Comparison of the Deep Optic Nerve Head Structure between Normal-Tension Glaucoma and Nonarteritic Anterior Ischemic Optic Neuropathy
نویسندگان
چکیده
PURPOSE To compare the deep optic nerve head (ONH) structure between normal-tension glaucoma (NTG) and nonarteritic anterior ischemic optic neuropathy (NAION) and also in healthy subjects as a control using enhanced depth imaging (EDI) spectral-domain optical coherence tomography (SD-OCT). METHODS This prospective cross-sectional study included 21 NAION patients who had been diagnosed as NAION at least 6 months prior to study entry, and 42 NTG patients and 42 healthy controls who were matched with NAION patients in terms of age, intraocular pressure (IOP), and optic disc area. The retinal nerve fiber layer (RNFL) thickness in the affected sector was also matched between NAION and NTG patients. The ONH was imaged using SD-OCT with the EDI technique. The anterior lamina cribrosa surface depth (LCD) and average prelaminar tissue (PT) thickness were measured in a sector of interest in each eye and compared among the three groups. RESULTS In the sector-matched comparison, LCD was largest in NTG patients, followed by NAION patients, while PT was thinner in NTG patients than in NAION patients (all P < 0.001). NAION patients had a comparable LCD and a thinner PT relative to normal controls (P = 0.170 and < 0.001, respectively). CONCLUSION The deep ONH configuration is strikingly different between NTG and NAION. The differing features provide comparative insight into the pathophysiology of the two diseases, and may be useful for differential diagnosis.
منابع مشابه
Bilateral nonarteritic anterior ischemic neuropathy following acute angle-closure glaucoma in a patient with iridoschisis: case report.
A 55-year-old woman was referred to our clinic because of a one-week history of visual loss and raised intraocular pressure in the left eye followed 4 days later by visual loss in the right eye. Slit-lamp examination showed bilateral conjunctival hyperemia, slight diffuse corneal edema, shallow anterior chamber and fixed and dilated pupil in both eyes. Splitting of the anterior layers of the ir...
متن کاملRadial optic neurotomy as a treatment for anterior ischemic optic neuropathy secondary to optic disc drusen
IMPORTANCE Radial optic neurotomy (RON) was first described by Opremcak as a treatment for patients with central retinal vein occlusion (CRVO). The most common cause of visual loss in patients with optic disc drusen is nonarteritic anterior ischemic optic neuropathy (NAION). The pathogenesis of nonarteritic anterior ischemic optic neuropathy associated with optic disc drusen is assumed to be si...
متن کاملClinical Usefulness of Spectral-Domain Optical Coherence Tomography in Glaucoma and NAION
The development of optical coherence tomography (OCT) has changed the clinical management of ophthalmic diseases by furthering the understanding of pathogenesis, as well as improving the monitoring of their progression and assisting in quantifying the response to treatment modalities in ophthalmic diseases. Initially, the two-dimensional configuration of the optic nerve head (ONH) and the thick...
متن کاملComparison of the Retinal Microvascular Density Between Open Angle Glaucoma and Nonarteritic Anterior Ischemic Optic Neuropathy.
Purpose To compare optical coherence tomography angiography (OCT-A) retinal vasculature measurements between nonarteritic anterior ischemic optic neuropathy (NAION) and open angle glaucoma (OAG) with altitudinal hemifield visual field defects. Methods This retrospective cross-sectional study included 10 NAION eyes and 16 OAG eyes, both demonstrating hemifield visual field defects, and 27 norm...
متن کاملIncidence of nonarteritic anterior ischemic optic neuropathy in adult Chinese: the Beijing Eye Study.
PURPOSE To determine the incidence of optic nerve damage due to nonarteritic anterior ischemic optic neuropathy (NAION) in the adult Chinese population. METHODS The Beijing Eye Study, a population-based, longitudinal study which included 4439 subjects (age 40+ years) in 2006, was repeated in 2006. In the follow-up examination, 3169 (71.4%) subjects participated. Optic disc photographs were as...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2016