Three-step method for ultrasound-guided central vein catheterization.
نویسندگان
چکیده
BACKGROUND The long-axis view and in-plane needle approach (LAX-IP) for ultrasound-guided central vein catheterization is considered ideal because of the quality of real-time imaging. We describe a novel technique, using a step-by-step procedure, to overcome the pitfalls associated with the LAX-IP. This study was undertaken to demonstrate the clinical utility of this approach. METHODS All operators underwent training before participation in this study. One hundred patients were enrolled in this study and underwent central venous catheterization using this method. Using a portable ultrasound and vein catheterization kit, patients were appropriately positioned and a straight portion of the vein identified (Step 1). A needle guide was used (Step 2) and the vein imaged in real time in two directions (Step 3), to identify the true long axis and prevent damage to surrounding tissues. RESULTS The overall success rate for catheterization was 100% with a median of one puncture for each patient. All catheterizations were performed within three punctures. Problems with the first puncture included difficult insertion of the guide-wire due to coiling, difficult anterior wall puncture, less experience with the procedure, and other reasons. There were no complications associated with the procedure. CONCLUSIONS This three-step method is not dependent on an operator's ability to proceed based on spatial awareness, but rather depends on logic. This method can prevent difficulties associated with a two-dimensional ultrasound view, and may be a safer technique compared with others. Further clinical trials are needed to establish the safety of this technique.
منابع مشابه
Ultrasound-guided catheterization of the internal jugular vein.
AIM To compare the traditional anatomic landmark technique with the ultrasound-guided method for central venous catheterization. MATERIAL AND METHODS During three years, 551 patients underwent internal jugular vein catheterization; in 347 patients, the ultrasound-guided technique was used, while in the other 204 patients the catheter was introduced by using the classical anatomic landmark met...
متن کاملFourth step for ultrasound-guided central vein catheterization.
Editor—We read with great interest the article by Tokumine and colleagues. The authors have introduced and demonstrated the safest method for central venous catheterization under real-time ultrasound guidance using the long-axis view of the vessel with the in-plane needle approach. As they have pointed out, the ultrasound-guided procedure with the short-axis view of the vessel with the out-of-p...
متن کاملUltrasound-guided infraclavicular axillary vein cannulation for central venous access.
BACKGROUND Infraclavicular axillary vein cannulation is not commonly used for central venous access because identifying the surface landmarks is difficult. Ultrasound guided axillary vein puncture has not been well described. We assessed ultrasound imaging to guide catheterization of the infraclavicular axillary vein. METHODS In 200 consecutive patients we attempted to catheterize the axillar...
متن کاملA new central venous access in Emergency Department: ultrasound-guided infraclavicular axillary vein
Results 52 year old woman addicted to parenteral drugs, stage C3 HIV with 2 weeks duration fever. On arrival had malaise, hypotensive, febrile, tachycardic... it was not possible to catheterize a peripheral vein we performed a central line cannulation: ultrasound-guided infraclavicular axillary vein. Less arterio-venous overlap and a greater distance between artery and vein and from vein to rib...
متن کاملThe real effectiveness of ultrasound guidance in subclavian venous access.
AIM The technique of ultrasound-guided subclavian cannulation was evaluated in our experience assessing the real effectiveness of such procedure. METHODS We have evaluated 297 subclavian cannulation, performed for the placement of central venous catheter both with landmark method (176 patients) and ultrasound guided technique (121 patients) to assess the real effectiveness of the ultrasound-g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 110 3 شماره
صفحات -
تاریخ انتشار 2013