Radiation dose evaluation in 3D rotation angiography and cone-beam computed tomography with a flat panel detector.
نویسندگان
چکیده
The aim of this study was to evaluate radiation dose in patients undergoing three-dimensional rotation angiography (3DRA) and cone-beam computed tomography (CBCT) using a flat panel detector (FPD). Radiation doses were measured for angiography equipment using small silicon-photodiode dosimeters that were implanted in various positions in tissues and organs within an anthropomorphic phantom of a standard Japanese adult male. Output signals from the dosimeters were read out on a computer, from which organ and effective doses were calculated according to guidelines published in International Commission on Radiological Protection Publication 103. Lens doses and effective doses obtained in this study were 1.6 mGy and 0.13 mSv for 3DRA, 20 mGy and 1.7 mSv for CBCT (normal mode). 3DRA provided substantial lens doses and effective dose reduction, which were 8% of the doses in CBCT (normal mode).
منابع مشابه
Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector.
We evaluated a new 3D angiography system with a flat panel detector (FPD) for its capabilitiy to acquire volume sets during a single rotation scan and to reconstruct high spatial resolution three-dimensional and cross sectional images, namely cone beam volume computed tomography (CBVCT) images. Present status of the technique, advantages and potential applications are discussed.
متن کاملDosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography
Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free.Objective: The aim of this study was to evaluate the exposure doses received by patients during maxillofacial imaging with CBCT.Methods: Entrance surface dose (ESD) was measured by using thermoluminescent dosimeters (TLDs) attached to the eyes...
متن کاملUsability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...
متن کاملA cone-beam volume CT using a 3D angiography system with a flat panel detector of direct conversion type: usefulness for superselective intra-arterial chemotherapy for head and neck tumors.
BACKGROUND AND PURPOSE The development of flat panel detectors (FPDs) has made cone-beam CT feasible for practical use in a clinical setting. Our purpose was to assess the usefulness of cone-beam CT using the FPD in conjunction with conventional digital subtraction angiography (DSA) for performing superselective intra-arterial chemotherapy for head and neck tumors. MATERIALS AND METHODS Twent...
متن کاملEvaluation of Cone Beam Computed Tomography in Diagnosis and Treatment Plan of Impacted Maxillary Canines
Introduction: Maxillary canines have important roles in facial appearance, development of arch, and functional occlusion. Radiographs are important in evaluating the location and nature of these anomalies. The purpose of this study was to evaluate two types of 2D and 3D imaging technique in diagnosis and treatment of maxillary impacted canines. Methods: Thirty eight patients (50 impacted canine...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nihon Hoshasen Gijutsu Gakkai zasshi
دوره 70 7 شماره
صفحات -
تاریخ انتشار 2014