Whole-body 18F-FDG PET/CT: the need for a standardized field of view--a referring-physician aid.

نویسندگان

  • Scott F Huston
  • Amir G Abdelmalik
  • Nghi C Nguyen
  • Hussein R Farghaly
  • Medhat M Osman
چکیده

UNLABELLED PET/CT fusion of anatomic and functional imaging modalities is in evolution, with rapid clinical dissemination. The imaged field of view (FOV) selected for whole-body PET/CT protocols is not standardized and varies by institution. Misuse of the term whole body, as well as the pressure to increase the number of daily studies by reducing scanning time, contributes to the lack of standardization. The purpose of this study was to evaluate variations in the FOV and arm positioning selected for whole-body PET/CT protocols at private, as well as academic, PET centers. METHODS Two hundred consecutive whole-body (18)F-FDG PET/CT studies were retrospectively reviewed for FOV: 50 studies from a private stationary site, 50 studies from 2 separate private mobile sites (25 consecutive studies from each), and 100 studies from a stationary university site: 50 before and 50 after implementation of a true whole-body protocol covering the top of the head through the bottom of the feet. Data were categorized into 5 different anatomic scan lengths: base of skull to upper thigh, base of skull to mid thigh, top of head to upper thigh, top of head to mid thigh, and true whole-body. Studies were further categorized into 2 patient arm positions: up and down. RESULTS The private stationary and mobile sites had only 2 categories of anatomic scan lengths identified: base of skull to mid thigh, and top of head to upper thigh. At the university site, before implementation of a true whole-body protocol, the 5 different anatomic scan lengths were identified; after implementation, only the true whole-body scan length was identified. Patients' arms in the private stationary sites were down 100% of the time. At the private mobile sites, patients' arms were up 72% of the time and down 28% of the time. At the university site, patients' arms were up 54% of the time and down 46% of the time. The same site, after implementation of a true whole-body protocol, had patients' arms up 58% of the time and down 42% of the time. Overall, patients' arms were up 46% of the time and down 54% of the time. CONCLUSION The continued use of the term whole body is misleading because frequently it may not include the brain, skull, or significant portions of the upper and lower extremities. PET/CT anatomic scan length varied not only from one site to the next but also within individual sites. The Centers for Medicare and Medicaid Services have different current procedural terminology codes distinguishing between base of skull to upper thigh and true whole-body covering the top of the skull to the bottom of the feet, thus underscoring the need to standardize the terminology used in describing PET/CT scan length.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Value of Dedicated Head and Neck 18F-FDG PET/CT Protocol in Detecting Recurrent and Metastatic Lesions in Post-surgical Differentiated Thyroid Carcinoma Patients with High Serum Thyroglobulin Level and Negative 131I Whole-body Scan

Objective(s): In clinical practice, approximately 10-25% of post-surgical differentiated thyroid carcinoma (DTC) patients with high serum thyroglobulin (Tg) and negative 131I whole-body scan (WBS) have poor prognosis due to recurrent or metastatic lesions after radioactive iodine treatment. The purpose of this study was to evaluate the value of 18F-FDG PET/CT scan in DTC patients with high seru...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

Rare ocular and skin lesions of Marginal Zone Lymphoma detected by 18F-FDG PET/CT

We report a case of a 75-year old man that came at hematologist’s attention for lymphoma evaluation due to axillary lymph node enlargement and fever. Thorax, abdomen and pelvis Contrast-Enhanced Computed Tomography (CECT) showed lymph nodes, spleen and liver lesions. Axillary lymph node biopsy was performed and the diagnosis of marginal zone lymphoma (MZL) at stage IV was postulated, then the p...

متن کامل

18F-FDG PET/CT in Neurolymphomatosis: Report of 3 Cases

Neurolymphomatosis is a rare manifestation of non-Hodgkin lymphoma characterized by infiltration of peripheral nerves, nerve roots, plexus and cranial nerves by malignant lymphocytes. This report presents positron emission tomography/computed tomography (PET/CT)imaging with 2-deoxy-2-18F-fluoro-D-glucose (18F-FDG) in 3 cases of non-Hodgkin lymphoma with nerve infiltration, including one newly d...

متن کامل

18F-FDG PET/CT of advanced gastric carcinoma and association of HER2 expression with standardized uptake value

Objective(s): Expression of HER2 in gastric carcinoma has direct prognostic and therapeutic implications in patient management. The aim of this study is to determine whether a relationship exists between standardized uptake value (SUV) and expression of HER2 in advanced gastric carcinoma. Methods: We analyzed the 18F-FDG PET/CT results of 109 patients that underwent gastrectomy for advanced gas...

متن کامل

Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST

Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 38 3  شماره 

صفحات  -

تاریخ انتشار 2010