The electromechanical (EM) impedance technique using piezoelectric lead zirconate titanate (PZT) transducers for structural health monitoring (SHM) has attracted considerable attention in various engineering fields. In the conventional EM impedance technique, the EM admittance of a PZT transducer is used as a damage indicator. Statistical analysis methods such as root mean square deviation (RMSD) have been employed to associate the damage level with the changes in the EM admittance signatures, but it is difficult to determine the location of damage using such methods. This paper proposes a new approach by dividing the large frequency (30-400 kHz) range into sub-frequency intervals and calculating their respective RMSD values. The RMSD of the sub-frequency intervals (RMSD-S) will be used to study the severity and location of damage. An experiment is carried out on a real size concrete structure subjected to artificial damage. It is observed that damage close to the PZT changes the high frequency range RMSD-S significantly, while the damage far away from the PZT changes the RMSD-S in the low frequency range significantly. The relationship between the frequency range and the PZT sensing region is also presented. Finally, a damage identification scheme is proposed to estimate the location and severity of damage in concrete structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of DSP-based Electromechanical (E/M) Impedance Analyzer for Active Structural Health Monitoring

The electromechanical (E/M) impedance method is a powerful technique in active structural health monitoring (SHM). E/M impedance method utilizes as its main apparatus an impedance analyzer that reads the in-situ E/M impedance of piezoelectric wafer active sensors (PWAS) attached to the monitored structure. Present-day impedance analyzer equipments (e.g.HP4194) are bulky, heavy and expensive lab...

متن کامل

Development of a Field-Portable Small-Size Impedance Analyzer for Structural Health Monitoring using the Electromechanical Impedance Technique

Electromechanical (E/M) impedance method is emerging as an effective and powerful technique for structural health monitoring. The E/M impedance method utilizes as its main apparatus an impedance analyzer that reads the in-situ E/M impedance of piezoelectric wafer active sensors (PWAS) attached to the monitored structure. Laboratory-type impedance analyzers (e.g. HP4194) are bulky, heavy, and ex...

متن کامل

A Study of Concrete Slab Damage Detection Based on the Electromechanical Impedance Method

Piezoelectric lead zirconate titanate (PZT) is being gradually applied into practice as a new intelligent material for structural health monitoring. In order to study the damage detection properties of PZT on concrete slabs, simply supported reinforced concrete slabs with piezoelectric patches attached to their surfaces were chosen as the research objects and the Electromechanical Impedance met...

متن کامل

A Preliminary Study on the Prediction of Damaged Areas on Ordinary Concrete and Lightweight Concrete Using Electromechanical Impedance Technique with Different Frequency Ranges

The electromechanical impedance (EMI) method for NDE uses a single piezoelectric material to act as an actuator and a sensor simultaneously, and the EMI method is suitable for structures with complex surfaces. However, this technique still has wide range of problems which needs to be investigated. For one, locating damaged areas on a host structure precisely is known to be extremely difficult a...

متن کامل

Ubiquitous Piezoelectric Sensor Network (UPSN)-Based Concrete Curing Monitoring for u-Construction

Recently, there has been increasing demand for high-rise buildings or wide-span bridges. These structures are constructed with a mount of mass concrete. However, the concrete might be susceptible to brittle fracture if the curing process is inadequate. Therefore, to prevent this drawback, it is essential to predict the strength development of concrete during the curing process. In addition, rea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010