Single standard calibration and data processing in flow injection titration based on concentration gradients

نویسندگان

  • M. C. U. Araújo
  • A. V. Santos
  • R. S. Honorato
  • C. Pasquini
چکیده

This paper describes use of gradients of concentration generated in flow injection (FI) systems to perform determinations based on points where the concentration of titrant and analyte are at stoichiometric ratio. Two procedures were developed. In one procedure the titrant is injected in a FI manifold and merges with the sample which is continuously pumped towards the detector. In the other procedure the sample is injected and merged with the titrant which is continuously pumped. Both techniques make use of concentration gradients of the sample or titrant generated in FI manifolds that contain a mixing chamber. This gradient is calibrated employing only one standard solution (usually the titrant) in order to convert any detector signal, obtained in the elapsed time after injection, to instantaneous concentration values. The flow system is microcomputer controlled and data are treated to locate points where the concentration of titrant and analyte are at the stoichiometric ratio. These points are found in abrupt changes of the signal x concentration curves obtained in the presence of the reaction. The method has been evaluated for determination of Fe(II) and acetic acid by spectrophotometric and conductimetric detection, respectively. Results show a mean relative standard deviation lower than 1%, an average accuracy of 1% and a high sampling processing capability (40 to 60 samples per hour).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of flow injection gradient titration based on the standard addition and dilution procedure to the determination of total acidity in vinegars and soft drinks.

The proposed approach relies on successive dilution of a solution containing a sample with standard addition and on titration of the solutions obtained until receiving a signal lower than the signal measured for the sample alone. Equations are derived for subsequent dilution factors for the automatic flow injection system applied. The overall calibration strategy including the possibility of pr...

متن کامل

FLOW INJECTIOW DETERMINATION OF FLUORIDE BY MURTN-ALUMINUM REAGEM WITH SPECTROEUORIMIETRIC DETECTION

A flow injection system is reported for the determination of fluoride based on its effects on the fluorescence intensity of Al-morin complex at pH 3.0 in ethanol-warn mixture. The effect of important parameters such as excitation and emission wavelengths, pH, reagents concenkations, flow rate of the carrier stream, sample injection volume, time of measurepent and interferences are reported. ...

متن کامل

Numerical Study of the Mass Transfer Effects on the Flow and Thermal Fields Structures under the Influence of Natural Convection

In this paper, a numerical study has been carried out for coupled mass, momentum and heat transfer in the field under effects of natural convection. For this purpose, the unsteady incompressible Navier-Stokes equations with the terms of the Buoyancy forces (due to temperature gradients), energy conservation and concentration (mass) transfer equations have been simultaneously solved using approp...

متن کامل

Sequential injection technique for automated titration: spectrophotometric assay of vitamin C in pharmaceutical products using cerium(IV) in sulfuric acid.

For the first time sequential injection analysis (SIA) technique has been employed for titrimetry. A new SI titrimetric spectrophotometric method for the assay of vitamin C in drug formulations was explored. The method is based on the oxidation reaction of vitamin C with cerium(IV) in sulfuric acid media using a spectrophotometer as a detector with the wavelength monitored at 410 nm. A 2(3) fac...

متن کامل

Flow Injection Spectrophotometric Determination of Sulphide by Catalytic Reduction of Toluidine Blue

Sulphide was determined spectrophotometrically at 628 nm and pH 6.7 based on its catalytic reduction of toluidine blue in the presence of Se(IV) using a flow injection system. After optimization of the measuring conditions the calibration curve was found linear up to 25 mg/mL and the detection limit was 0.3 mg/mL (30 mL injections). The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 19  شماره 

صفحات  -

تاریخ انتشار 1997