Robust atomic force microscopy using multiple sensors.
نویسندگان
چکیده
Atomic force microscopy typically relies on high-resolution high-bandwidth cantilever deflection measurements based control for imaging and estimating sample topography and properties. More precisely, in amplitude-modulation atomic force microscopy (AM-AFM), the control effort that regulates deflection amplitude is used as an estimate of sample topography; similarly, contact-mode AFM uses regulation of deflection signal to generate sample topography. In this article, a control design scheme based on an additional feedback mechanism that uses vertical z-piezo motion sensor, which augments the deflection based control scheme, is proposed and evaluated. The proposed scheme exploits the fact that the piezo motion sensor, though inferior to the cantilever deflection signal in terms of resolution and bandwidth, provides information on piezo actuator dynamics that is not easily retrievable from the deflection signal. The augmented design results in significant improvements in imaging bandwidth and robustness, especially in AM-AFM, where the complicated underlying nonlinear dynamics inhibits estimating piezo motions from deflection signals. In AM-AFM experiments, the two-sensor based design demonstrates a substantial improvement in robustness to modeling uncertainties by practically eliminating the peak in the sensitivity plot without affecting the closed-loop bandwidth when compared to a design that does not use the piezo-position sensor based feedback. The contact-mode imaging results, which use proportional-integral controllers for cantilever-deflection regulation, demonstrate improvements in bandwidth and robustness to modeling uncertainties, respectively, by over 30% and 20%. The piezo-sensor based feedback is developed using H∞ control framework.
منابع مشابه
Covalent immobilization of molecularly imprinted polymer nanoparticles on a gold surface using carbodiimide coupling for chemical sensing.
One challenging task in building (bio)chemical sensors is the efficient and stable immobilization of receptor on a suitable transducer. Herein, we report a method for covalent immobilization of molecularly imprinted core-shell nanoparticles for construction of robust chemical sensors. The imprinted nanoparticles with a core-shell structure have selective molecular binding sites in the core and ...
متن کاملProbing Surface Spin Interaction Dynamics using Nitrogen-Vacancy Center Quantum Sensors with High-Fidelity State-Selective Transition Control
As a demand from developing nanotechnology and quantum information technology based on mesoscopic material, quantum sensors with better spatial resolution and sensitivity are required. However, few material meets the requirements of nanoscale sensors including stability and small size. Single spin of Nitrogen-Vacancy(NV) centers in diamond crystal is one kind of the ideal quantum sensors for ma...
متن کاملHybrid SnO2/TiO2 Nanocomposites for Selective Detection of Ultra-Low Hydrogen Sulfide Concentrations in Complex Backgrounds
In this paper, we present a chemiresistive metal oxide (MOX) sensor for detection of hydrogen sulfide. Compared to the previous reports, the overall sensor performance was improved in multiple characteristics, including: sensitivity, selectivity, stability, activation time, response time, recovery time, and activation temperature. The superior sensor performance was attributed to the utilizatio...
متن کاملAtomic Force Microscopy
The basic principles of atomic force microscopy are discussed. Various deflection sensors are described and compared with each other. A simple theoretical basis of the fundamental forces, such as van der Waals, electrostatic, magnetic, capillary, ionic repulsion and frictional forces, is given and the relevant experimental work is summarized.
متن کاملScanning force microscopy in the dynamic mode using microfabricated capacitive sensors
We report on the first successful operation of a scanning force microscope using microfabricated capacitive force sensors. The sensors, which are made from single crystal silicon on insulator wafers, consist of a cantilever spring with integrated tip at the free end and an electrically insulated counter electrode. Dynamic force gradient sensing is the preferred operating mode. Here, tip– sample...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 87 8 شماره
صفحات -
تاریخ انتشار 2016