BACKGROUND AND PURPOSE Substantial bone loss in revision total knee arthroplasty (TKA) is a challenging problem. We studied whether impaction bone grafting provides long-term restoration of bone stock in the treatment of major bone defects in revision surgery of rotational and hinged knee arthroplasties (LINK Endo-Model). PATIENTS AND METHODS Between 1996 and 2006, 29 knees in 29 patients underwent revision procedures of rotational and hinged knee arthroplasties using impaction bone grafting (IBG) to reconstruct major bone defects. At the latest follow-up, the clinical examination included the Knee Society score (KSS), standardized radiographs, and a questionnaire for the WOMAC score. RESULTS After a mean follow-up of 10 (6-13) years, 14 knees with 19 IBG reconstructions (5 total, 9 partial revisions) had failed. 12 knees were treated with re-revision surgery mean 5 (1-12) years after the first revision, due to mechanical failure and aseptic loosening of the components. In all these failed cases, the surgeon observed a lack of incorporation with bone graft resorption in the femur or tibia during the re-revision procedure. In all 15 knees that were not re-revised, with 21 reconstructions (6 total, 9 partial revisions), an improvement in the combined KSS score (knee score + function score) of 60 points (p < 0.001) was found at the latest follow-up. In 12 of these knees, a clear incorporation with no visible radiolucent lines around the component and no sign of substantial graft resorption was noted, while unclear radiographic graft incorporation was seen in 3 knees. INTERPRETATION Our results clearly indicate that IBG alone is not a methodologically sound technique in the revision of rotational and hinged knee arthroplasties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impaction bone grafting for tibial defects in knee replacement surgery. Results at two years.

Bone loss with large defects poses a complex and challenging problem in primary and revision knee arthroplasty. The defects are often irregular and difficult to quantify. One of the techniques available to restore bone in such cases is Knee Impaction Bone Grafting (KIBG); however, the clinical literature to support this technique is weak. Since 2006 we have used impaction bone grafting for cont...

متن کامل

Impaction bone grafting in revision hip surgery. A high incidence of complications.

We have reviewed retrospectively 68 revisions of the femoral component in arthroplasties of the hip in 65 patients, using impaction bone grafting, at a median of three years (1 month to 6 years). We employed the cemented Exeter X-Change technique in 36 patients and the uncemented Bi-Metric allografting method in 32. The 37 bone defects were grade 3 or grade 4 on the Endo-Klinik classification. ...

متن کامل

Filling of segmental bone defects in revision knee arthroplasty using morsellized bone grafts contained within a metal mesh.

For revision knee surgery with uncontained tibial bone defects, the authors report the containment of compacted morsellized allograft using metal-wire mesh, followed by implantation of a cemented total knee prosthesis. This method is comparable to the "impaction grafting technique" described for revision hip surgery and could be an alternative to metal wedges, augmented components, custom-made ...

متن کامل

A Comparative Biomechanical Analysis

J Bone Joint Surg [Br] 2009;91-B:271-7. Received 16 June 2008; Accepted after revision 26 September 2008 The treatment of bony defects of the tibia at the time of revision total knee replacement is controversial. The place of compacted morsellised bone graft is becoming established, particularly in contained defects. It has previously been shown that the initial stability of impaction-grafted t...

متن کامل

A sliding stem in revision total knee arthroplasty provides stability and reduces stress shielding

BACKGROUND AND PURPOSE In the reconstruction of unicondylar femoral bone defects with morselized bone grafts in revision total knee arthroplasty, a stem extension appears to be critical to obtain adequate mechanical stability. Whether stability is still assured by this reconstruction technique in bicondylar defects has not been assessed. The disadvantage of relatively stiff stem extensions is t...

متن کامل