Balloon-protected carotid artery stenting: relationship of periprocedural neurological complications with the size of particulate debris.

نویسندگان

  • T Tübler
  • M Schlüter
  • O Dirsch
  • H Sievert
  • I Bösenberg
  • E Grube
  • J Waigand
  • J Schofer
چکیده

BACKGROUND Carotid artery stenting (CAS) has been advocated as an alternative to endarterectomy. To prevent cerebral atheroembolism during CAS, distal balloon occlusion of the target artery increasingly is employed during the procedure. A correlation of the size of captured particles with the incidence of periprocedural neurological complications (PNCs) has not been attempted. METHODS AND RESULTS In a 4-center, phase-1 trial, 54 patients (46 men; age, 69+/-8 years) underwent 58 CAS procedures using the PercuSurge GuardWire system for distal protection. Aspirated debris was sent for histological/cytological analysis. Stent placement was successful in all cases. Mean balloon occlusion time was 10.4+/-4.0 minutes (range, 3.0 to 22.0 minutes). Three patients (5.2%) experienced PNCs: 1 prolonged reversible ischemic neurological deficit that resolved in /=10 000 micrometer(2)) were found in 48 aspirates (83%). The median number of particles, their maximum diameter, and their maximum area were all significantly higher in the aspirates obtained during procedures associated with PNCs than in aspirates obtained during procedures not associated with PNCs. However, pronounced overlap in the distributions (PNCs versus no PNCs) of the number and maximum diameter of particles precluded any predictive inferences. In contrast, a maximum particle area >800 000 micrometer(2) (>0.8 mm(2)) was associated with a 60% chance of having a PNC. CONCLUSIONS Despite balloon protection, PNCs occurred in 5.2% of patients who underwent CAS procedures. The maximum area of aspirated particles seems to be an indicator of increased risk for PNCs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

A New Concept for Carotid Artery Stenting: Coating the Atherosclerotic Plaque by Covered Stent before Bare Stent Implantation.

In carotid artery stenting (CAS) procedures, distal embolism, periprocedural stent thrombosis, and 30-day stroke due to the plaque fragmentation and protrusion caused by stent implantation and balloon dilation are frequent complications. In this technical case report, a case is presented of extracranial carotid artery stenosis treated with a covered stent and subsequent implantation of a bare s...

متن کامل

Carotid artery stenting protected with an emboli containment system.

BACKGROUND AND PURPOSE Fear of distal embolization and stroke has aroused concern regarding carotid stenting. Devices to protect the cerebral circulation may make carotid stenting safer. METHODS A multidisciplinary study group tested a balloon occlusion-aspiration emboli entrapment device in conjunction with carotid stenting. The device consists of an elastomeric balloon on a steerable wire w...

متن کامل

Volume and composition of emboli in neuroprotected stenting of the carotid artery.

BACKGROUND AND PURPOSE Periprocedural microembolization is a major and permanent risk for patients treated by angioplasty and stent placement of high-grade carotid stenoses. Little is known however about the characteristics and significance of these embolized particles. Our aim was to assess the volume and composition of debris captured by filters during carotid angioplasty and stent placement ...

متن کامل

Use of a large angioplasty balloon for predilation is a risk factor for embolic complications in protected carotid stenting.

Periprocedural neurological complications (PNCs) after carotid stenting were retrospectively analyzed to determine the risk factors with the use of various protective devices. Forty-three lesions in 40 patients were treated by carotid stenting with distal balloon protection for nearly all postdilation procedures and some predilation procedures. The following variables were statistically analyze...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 104 23  شماره 

صفحات  -

تاریخ انتشار 2001