Steerable versus nonsteerable sheath technology in atrial fibrillation ablation: a prospective, randomized study.

نویسندگان

  • Christopher Piorkowski
  • Charlotte Eitel
  • Sascha Rolf
  • Kerstin Bode
  • Philipp Sommer
  • Thomas Gaspar
  • Simon Kircher
  • Ulrike Wetzel
  • Abdul Shokor Parwani
  • Leif-Hendrik Boldt
  • Meinhard Mende
  • Andreas Bollmann
  • Daniela Husser
  • Nikolaos Dagres
  • Masahiro Esato
  • Arash Arya
  • Wilhelm Haverkamp
  • Gerhard Hindricks
چکیده

BACKGROUND Steerable sheath technology is designed to facilitate catheter access, stability, and tissue contact in target sites of atrial fibrillation (AF) catheter ablation. We hypothesized that rhythm control after interventional AF treatment is more successful using a steerable as compared with a nonsteerable sheath access. METHODS AND RESULTS One hundred thirty patients with paroxysmal or persistent drug-refractory AF undergoing their first ablation procedure were prospectively included in a randomized fashion in 2 centers. Ablation was performed by 10 operators with different levels of clinical experience. Treatment outcome was measured with serial 7-day Holter ECGs and additional symptom-based arrhythmia documentation. Single procedure success (freedom from AF and/or atrial macroreentrant tachycardia) was significantly higher in patients ablated with a steerable sheath (78% versus 55% after 3 months, P=0.005; 76% versus 53% after 6 months, P=0.008). Rate of pulmonary vein isolation, procedure duration, and radiofrequency application time did not differ significantly, whereas fluoroscopy time was lower in the steerable sheath group (33±14 minutes versus 45±17 minutes, P<0.001). Complication rates showed no significant difference (3.2% versus 5%, P=0.608). On multivariable analysis, steerable sheath usage remained the only powerful predictor for rhythm outcome after 6 months of follow-up (hazard ratio, 2.837 [1.197 to 6.723]). CONCLUSIONS AF catheter ablation using a manually controlled, steerable sheath for catheter navigation resulted in a significantly higher clinical success rate, with comparable complication rates and with a reduction in periprocedural fluoroscopy time. CLINICAL TRIAL REGISTRATION URL: http://clinicaltrials.gov. Unique identifier: NCT00469638.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin

  Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation.   A total of 100 patients with AF w...

متن کامل

Effect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin

  Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation.   A total of 100 patients with AF w...

متن کامل

Commentary: Virtual In-Silico Modeling Guided Catheter Ablation Predicts Effective Linear Ablation Lesion Set for Longstanding Persistent Atrial Fibrillation: Multicenter Prospective Randomized Study

Citation: Loewe A and Dössel O (2017) Commentary: Virtual In-Silico Modeling Guided Catheter Ablation Predicts Effective Linear Ablation Lesion Set for Longstanding Persistent Atrial Fibrillation: Multicenter Prospective Randomized Study. Front. Physiol. 8:1113. doi: 10.3389/fphys.2017.01113 Commentary: Virtual In-Silico Modeling Guided Catheter Ablation Predicts Effective Linear Ablation Lesio...

متن کامل

Epicardial phrenic nerve displacement during catheter ablation of atrial and ventricular arrhythmias: procedural experience and outcomes.

BACKGROUND Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. METHODS AND RESULTS PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation trigger...

متن کامل

PentaRay entrapment in a mechanical mitral valve during catheter ablation of atrial fibrillation

Figure 1 Retrieval of sheared PentaRay remnant. Still-frame fluoroscopy image in anteroposterior view demonstrating the Jawz Biopsy Forcep and steerable Agilis sheath directed toward the catheter remnant in the area of the antrum of the right inferior pulmonary vein. Case report A 32-year-old woman with a mechanical Carbomedics (Sorin Group, Milan, Italy) bileaflet MV for MV endocarditis in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2011