Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery.

نویسندگان

  • Karsten Knobloch
  • Artur Lichtenberg
  • Michael Winterhalter
  • Dagmar Rossner
  • Max Pichlmaier
  • Rob Phillips
چکیده

PURPOSE This study was to compare noninvasive measurement of cardiac output (CO) using a novel Doppler technique with invasive CO measurements in the postcardiac surgical intensive care unit. DESCRIPTION Thirty-six patients (67.2 +/- 10 years, New York Heart Association functional class 3.1 +/- 0.3) undergoing coronary revascularization were prospectively examined postoperatively. One hundred eighty paired CO and stroke volume measurements were compared from the noninvasive USCOM device (Sydney, Australia) and the invasive Swan-Ganz catheter at varying COs. Eighteen measurements were performed intraoperatively by direct insonation of the right ventricular outflow tract. EVALUATION Mean noninvasive and invasive CO values were 5.15 +/- 1.98 L/min and 4.92 +/- 2.0 L/min, respectively (r = 0.870; p < 0.01). The mean difference between methods was -0.23 +/- 1.01 L/min greater than a range of CO values from 2.5 to 9.9 L/min. Mean central venous saturation percentage was 72 +/- 9%, correlating with both noninvasive and invasive CO (r = 0.474 and 0.606, respectively, p < 0.01). Intraoperatively, both direct and invasive CO were identical. CONCLUSIONS Using the ultrasonic cardiac output monitoring (USCOM) device it is possible to determine noninvasive beat-to-beat CO in postcardiac surgery patients without the possible complications associated with invasive right heart catheterization. The USCOM CO and stroke volume showed a very good agreement with invasive Swan-Ganz measures and correlated with central venous saturation percentage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of stroke volume and cardiac output during exercise: comparison of two-dimensional and Doppler echocardiography, Fick oximetry, and thermodilution.

Simultaneous estimates of cardiac output were made during graded upright maximal exercise in 10 male subjects by means of Doppler velocity spectrum of ascending aortic flow, apical two-dimensional echocardiograms, thermodilution, and Fick oximetry. In 15 subjects, aortic annular and root diameters were measured during similar exercise from parasternal two-dimensional echocardiograms. The linear...

متن کامل

Non-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis

In this study, a method for non-invasive estimation of stress on the heart wall in  the diastole phase is presented using ultrasound echocardiography and tissue Doppler  imaging. The aim of this study was to evaluate the stress on the heart wall as a  pre-diagnosis  to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...

متن کامل

A comparison of the non-invasive ultrasonic cardiac output monitor (USCOM) with the oesophageal Doppler monitor during major abdominal surgery.

BACKGROUND Perioperative interventions, targeted to increase global blood flow defined by explicit measured goals, reduce postoperative complications. Consequently, reliable non-invasive estimation of the cardiac output could have far-reaching benefit. METHODS This study compared a non-invasive Doppler device - the ultrasonic cardiac output monitor (USCOM) - with the oesophageal Doppler monit...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 80 4  شماره 

صفحات  -

تاریخ انتشار 2005