Monitoring the behaviour of 4-ketocyclophosphamide versus cyclophosphamide during capillary gas chromatography by mass spectrometry.

نویسندگان

  • E A de Bruijn
  • A T van Oosterom
  • P A Leclercq
  • J W de Haan
  • L J van de Ven
  • U R Tjaden
چکیده

Capillary Gas Chromatography (CGC) is capable of determining underivatized cyclophosphamide (CPA) using SCOT OV 275 columns. Then CPA is subjected to in situ degradation resulting in formation of a cyclization product which can be determined selectively in biological fluids. In routine bioanalysis however cyclization products of CPA metabolites might interfere, e.g. 4-keto CPA. In the present study possible formation of cyclization products of 4-keto CPA similar to CPA was monitored by Mass Spectrometry. Cyclization of 4-keto CPA in situ was demonstrated to occur, resulting in a product similar to that of CPA. Both cyclization products could be determined selectively and it appeared that in situ cyclization of 4-keto CPA was negligible (less than 5%), probably owing to extra stabilization of the CPA metabolite by keto-enol tautomerism as has been demonstrated by NMR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of cyclophosphamide metabolites by gas chromatography and thermionic specific detection. Interindividual differences in hepatic biotransformation of cyclophosphamide in man in vitro.

Sensitive methods for the determination of the cyclophosphamide metabolites nornitrogen mustard, 4-ketocyclophosphamide and carboxyphosphamide are presented. After liquid-liquid extraction and derivatization, the metabolites are determined by gas chromatography and thermionic specific detection. The methods were used to study the in vitro biotransformation of cyclophosphamide with S-9 liver fra...

متن کامل

Comparative metabolism of 2-[bis(2-chloroethyl)amino]tetrahydro-2-H-1,3,2-oxazaphosphorine-2-oxide (cyclophosphamide) and its enantiomers in humans.

The comparative metabolism of the enantiomers of cyclo phosphamide and of the racemate has been studied in humans. Four patients were each given, sequentially, the racemate, the (+)-enantiomer, and its (-)-antipode. The plasma levels of parent drug and the urinary output (24 hr) of unchanged drug and of two enzymatically produced metabolites, 4-ketocyclophosphamide and carboxyphosphamide, were ...

متن کامل

Supercritical fluid chromatography and microbore liquid chromatography for drug analysis.

Supercritical fluid and microbore liquid chromatography offer potential applications for drug analysis. In supercritical fluid chromatography (SFC), the mobile phase is a gas (e.g., carbon dioxide) maintained at its supercritical state--that is, above its critical temperature and pressure, above which it cannot be liquefied even with further increases in applied pressure. The SFC mobile phase h...

متن کامل

Measurement of rimantadine in plasma by capillary gas chromatography/mass spectrometry with a deuterium-labeled internal standard.

Rimantadine is a synthetic antiviral agent used in prophylaxis and in treating the early stages of uncomplicated influenza A illness. We describe a stable isotope-dilution assay involving capillary gas chromatography/mass spectrometry. We used 200 ng of d3-rimantadine, added to 1 mL of plasma, as the internal standard. The rimantadine was extracted from the plasma with a Bond-Elut CN column, th...

متن کامل

Impact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study

In this study, a simple and reliable method by gas chromatograph–mass spectrometry (GC–MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC–MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method sh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical & environmental mass spectrometry

دوره 14 11  شماره 

صفحات  -

تاریخ انتشار 1987