A technique to remove a broken guide wire transfixing the hip joint.

نویسندگان

  • Hemant Sharma
  • Manish Chauhan
  • Lalit Maini
چکیده

A broken guide wire while operating on hip is one of every surgeon's most dreaded nightmares. We report here a method which was used successfully to retrieve a broken guide wire from a patient who was being operated for core decompression and fibular grafting for avascular necrosis of the femoral head.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

  During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementa...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture.

During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementatio...

متن کامل

New method to remove a broken guide pin in the hip joint.

Removing a broken guide wire is difficult and challenging. This article reports a method that was used to successfully remove a broken guide wire in 3 patients who underwent operative treatment for intertrochanteric fractures of the femur. Under general anesthesia, the first patient was placed on the orthopedic fracture table, and closed reduction of the hip fracture was performed under the ima...

متن کامل

رابطه گشتاور نسبی ایزوکینتیک مفاصل ران، زانو و مچ پا با ارتفاع پرش با پای راهنما در مردان جوان

Objective: The aim of this study was to investigate the relationship between isokinetic relative torques of hip, knee and ankle joints and the height of guide leg jump in young men. Methods: 27 college male athletes with mean age of 25±3.5 years, height 178.5±7.8 cm and weight of 75.7±10.7 kg voluntarily participated in this study. Isokinetic torque of hip, knee and ankl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 74 5  شماره 

صفحات  -

تاریخ انتشار 2008