A glass fiber sheet-based electroosmotic lateral flow immunoassay for point-of-care testing.

نویسندگان

  • Yuriko Oyama
  • Toshihisa Osaki
  • Koki Kamiya
  • Ryuji Kawano
  • Tsutomu Honjoh
  • Haruki Shibata
  • Toru Ide
  • Shoji Takeuchi
چکیده

We have developed a quantitative immunoassay chip targeting point-of-care testing. To implement a lateral flow immunoassay, a glass fiber sheet was chosen as the material for the microfluidic channel in which the negative charge on the fiber surfaces efficiently generates the electroosmotic flow (EOF). The EOF, in turn, allows controllable bound/free separation of antigen/antibody interactions on the chip and enables precise determination of the antigen concentration. In addition, the defined size of the porous matrix was suitable for the filtration of undesired large particles. We confirmed the linear relationship between the concentration of analyte and the resulting fluorescence intensity from the immunoassay of two model analytes, C-reactive protein (CRP) and insulin, demonstrating that analyte concentration was quantitatively determined within the developed chip in 20 min. The limits of detection were 8.5 ng mL(-1) and 17 ng mL(-1) for CRP and insulin, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glass Fiber Sheet on a Chip: for Rapid, Low-cost, and Contamination-free Quantitative Immunoassay

This paper describes a quantitative immunoassay chip harnessing EOF (electroosmotic flow) in glass fiber sheet. The chip consists of a glass fiber sheet-based channel covered with PMMA (polymethylmethacrylate) frames and antibody-immobilized microbeads at the observation spot (Fig. 1). Applying EOF, another labeled-antibody and rinsing buffer sequentially migrate through the antigen-antibody co...

متن کامل

Measurement of Urinary N-Telopeptides and Serum C-Telopeptides from Type I Collagen Using a Lateral Flow-Based Immunoassay

Measuring bone turnover markers could detect early stages of osteoporosis and early responses to anti-osteoporotic treatments. Currently, commonly used bone turnover markers, N-telopeptides (NTx) and C-telopeptides (CTx), are measured using ELISA tests, which demands time and increases cost. Bone turnover markers need to be measured more easily for general use. Lateral flow-based immunoassay wo...

متن کامل

Experimental investigation of the strength of glass fiber-reinforced concrete exposed to high temperature

This study investigated the effects of high temperature exposure on the compressive, tensile, and flexural strengths of concrete containing glass fiber. A total of 108 cubic specimens (150 mm × 150 mm × 150 mm), cylindrical specimens (300 mm × 150 mm), and prismatic specimens (500 mm × 150 mm × 150 mm) were prepared for compressive, tensile, and flexural strength testing, respectively. The spec...

متن کامل

Development of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies

Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 12 24  شماره 

صفحات  -

تاریخ انتشار 2012