Fatigue testing of three peristernal median sternotomy closure techniques
نویسندگان
چکیده
BACKGROUND Failure of a sternotomy closure because of closure system fatigue is a complication that may result in dehiscence and put the individual at risk for serious complications. The purpose of this study was to assess the fatigue performance of three peristernal median sternotomy closure techniques (figure-of-eight stainless-steel wires, figure-of-eight stainless-steel cables, or Pectofix Dynamic Sternal Fixation [DSF] stainless-steel plates) in order to quantify the potential risk of fatigue failure of these devices when subject to cyclic loads in physiologically relevant loading directions. STUDY DESIGN All tests were conducted on polyurethane foam sternal models. A cardiothoracic surgeon divided each sternal model longitudinally and repaired it with a closure device. Tests were performed using a materials testing system that applied cyclic loading in a uniaxial direction until the test model catastrophically broke or data run-out occurred. For each loading direction (lateral distraction and longitudinal shear), five trials of each closure technique were tested. Life data and location of device failure (if present) were evaluated. Statistical analysis was performed using regression with life data allowed for correlation between life data and the various closure techniques to develop risk assessment curves for each device. RESULTS The data show that the figure-of-eight stainless-steel cable and the DSF plate systems are considerably less likely to fail under both lateral distraction and longitudinal shear cyclic loading conditions as compared to the figure-of-eight stainless-steel wire system. Moreover, the figure-of-eight stainless-steel cable system is the most resistant to failure, particularly for high cycle counts. CONCLUSION This study in addition to Cohen and Griffin's earlier published biomechanical comparison of the ultimate strength of these same three closure techniques provide extensive experimental evidence regarding the mechanical differences among these three peristernal median sternotomy closure techniques. All data support the hypothesis that both the DSF plate system and the stainless-steel cable system offer important advantages over figure-of-eight wire closure techniques; although twisted wires are the weak-link in the systems we tested.
منابع مشابه
Fatigue testing median sternotomy closures.
OBJECTIVE Sternal dehiscence is commonly due to wire cutting through bone. With a biological model, we measured the rate of cutting through bone, of standard steel wire closure, peristernal steel wire, figure-of-eight closure, polyester and sternal bands sternotomy closure techniques. METHODS Polyester, figure-of-eight, peristernal and sternal band closures were tested against standard closur...
متن کاملReduction in deep sternal wound infection with use of a peristernal cable-tie closure system: a retrospective case series
BACKGROUND Deep sternal wound infections are a rare but serious complication after median sternotomy. We evaluated the incidence of deep sternal wound infection associated with two techniques for sternal closure. METHODS In this retrospective case series, we recorded the method of sternal closure in consecutive patients undergoing a variety of cardiothoracic surgical procedures. Sternal closu...
متن کاملPii: S1010-7940(01)00807-7
We read with interest the recent article by Casha et al. [1] on fatigue testing median sternotomy closures. Their model is based on 2.5-cm cut samples of sheep sternal bones, wired in the standard trans-sternal, ®gure-eight, and peristernal fashion; additionally, no. 5 gauge polyester and stainless steel bands were used. The authors conclude that use of polyester and ®gure-eight closures requir...
متن کاملمقایسه نتایج زودرس عمل جراحی ترمیم نقص دیواره بین دهلیزی به دو روش توراکوتومی محدود و استرنوتومی میانی (در مدت پنج سال)
Background and Aim: According to previous studies, surgical closure of atrial septal defects (ASDs) was considered as the standard treatment. Two surgical methods, the conventional sternotomy (CSA: median sternotomy) and anterlateral thoracotomy were used. This study was carried out to compare early results of the two techniques in ASD's closure. Materials and Methods: In this descriptive-anal...
متن کاملA new technical approach for sternal closure with suture anchors (Dogan technique).
OBJECTIVES Various methods for sternal approximation have been described previously. Some patients undergoing these procedures are at risk for sternal dehiscence and mediastinitis. We used a different method, with a suture anchor system, for median sternotomy closure as an alternate technique in patients with a high risk of postoperative sternal dehiscence and sternal nonunion. MATERIAL AND M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Cardiothoracic Surgery
دوره 3 شماره
صفحات -
تاریخ انتشار 2008