The long-term anterior segment configuration after pediatric cataract surgery and the association with secondary glaucoma

نویسندگان

  • Ding Chen
  • Xian-hui Gong
  • He Xie
  • Xue-ning Zhu
  • Jin Li
  • Yun-e Zhao
چکیده

Secondary glaucoma constitutes major sight-threatening complication of pediatric cataract surgery, yet the etiology remains unclear. The purpose of this study was to investigate the long-term anterior segment configuration and the association with secondary glaucoma in pediatric pseudophakia. Ultrasound biomicroscopy (UBM) was performed on 40 eyes of 26 children underwent pediatric cataract surgery and intraocular lens (IOL) implantation. The anterior chamber depth (ACD), angle-opening distance at 500 μm (AOD500), trabecular-iris angle (TIA), central corneal thickness (CCT), structural abnormities, IOL position, IOP, and incidence of glaucoma were evaluated. High insertion of iris, in which the iris root is attached more anteriorly than normal, was seen in 13 eyes (32.50%). IOL was located in the capsular bag in 19 eyes and in the ciliary sulcus in 21 eyes. Logistic regression analysis identified high insertion of iris (OR 3.40, 95% CI 1.03-11.17, p = 0.03) and IOL implantation in sulcus (OR 1.39, 95% CI 1.07-4.85, p = 0.04) as independent risk factors for glaucoma. The presence of high insertion of iris and IOL implantation in ciliary sulcus may increase the long-term risk of the development of secondary glaucoma after pediatric cataract surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Phacoemulsification on Intraocular Pressure in Eyes with Pseudoexfoliation Single-surgeon Series Polypropylene Suture-guided Valve Tube for Posterior Chamber Implantation in Patients with Pseudophakic Glaucoma

Pseudoexfoliation (PFX) is characterized by the abnormàl production and accumulation of a fibrillar extracellular material with a gray appearance in the anterior segment of the eye and other tissues of the body. It is the most common identifiable cause of open-angle glaucoma, and there is an etio1oical association between PFX and cataract formation. Complication rates for cataract surgery in ey...

متن کامل

Anterior segment configuration as a predictive factor for refractive outcome after cataract surgery in patients with glaucoma

BACKGROUND To compare refractive outcomes after cataract surgery between patients with closed-angle and open-angle glaucoma and evaluate the influence of preoperative factors on refractive outcomes in patients with glaucoma. METHODS Patients diagnosed with glaucoma and who underwent uncomplicated cataract surgery were enrolled in this retrospective observational study. We collected data inclu...

متن کامل

Corticotherapy in Eye Diseases and Its Complications

Corticosteroids are being rn;;ed in different ophthalmic disorder as anti-inflamatory agent.  A.C.T.H. stimulated the supra renal glands and causes an increase steroid concentration of the blood. Corticosteroids can be used as anti­inflamatory agent locally ar.d systemically.  The new corticom,teroids like prednison, dex­xametason and prednisolon are more effective ( 5 to 10 times) than the o...

متن کامل

Long-term outcomes of ciliary sulcus versus capsular bag fixation of intraocular lenses in children: An ultrasound biomicroscopy study

PURPOSE To evaluate the long-term outcomes of ciliary sulcus versus capsular bag fixation of intraocular lenses (IOLs) in children after pediatric cataract surgery. METHODS IOL was implanted in the ciliary sulcus in 21 eyes of 14 children, and in the capsular bag in 19 eyes of 12 children for the treatment of pediatric cataract in an institutional setting. Ultrasound biomicroscopy (UBM) was p...

متن کامل

Anterior segment optical coherence tomography for evaluation of changes in anterior chamber angle and depth after intraocular lens implantation in eyes with glaucoma.

PURPOSE To examine anterior chamber depth (ACD) and anterior chamber angle (ACA) in patients with glaucoma after cataract extraction with an anterior optical coherence tomography (OCT) system. METHODS A new commercially available 1310 nm infrared light anterior segment OCT system was used for anterior chamber evaluation. Sixty patients (n=20 with primary open angle glaucoma [POAG], n=20 with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017