Neonatal resuscitation 1: a model to measure inspired and expired tidal volumes and assess leakage at the face mask.

نویسندگان

  • C P F O'Donnell
  • C O F Kamlin
  • P G Davis
  • C J Morley
چکیده

BACKGROUND Neonatal resuscitation is a common and important intervention, and adequate ventilation is the key to success. In the delivery room, positive pressure ventilation is given with manual ventilation devices using face masks. Mannequins are widely used to teach and practise this technique. During both simulated and real neonatal resuscitation, chest excursion is used to assess tidal volume delivery, and leakage from the mask is not measured. OBJECTIVE To describe a system that allows measurement of mask leakage and estimation of tidal volume delivery. METHODS Respiratory function monitors, a modified resuscitation mannequin, and a computer were used to measure leakage from the mask and to assess tidal volume delivery in a model of neonatal resuscitation. RESULTS The volume of gas passing through a flow sensor was measured at the face mask. This was a good estimate of the tidal volume entering and leaving the lung in this model. Gas leakage between the mask and mannequin was also measured. This occurred principally during inflation, although gas leakage during deflation was seen when the total leakage was large. A volume of gas that distended the mask but did not enter the lung was also measured. CONCLUSION This system can be used to assess the effectiveness of positive pressure ventilation given using a face mask during simulated neonatal resuscitation. It could be useful for teaching neonatal resuscitation and assessing ventilation through a face mask.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neonatal resuscitation 3: manometer use in a model of face mask ventilation.

BACKGROUND Adequate ventilation is the key to successful neonatal resuscitation. Positive pressure ventilation (PPV) is initiated with manual ventilation devices via face masks. These devices may be used with a manometer to measure airway pressures delivered. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal...

متن کامل

Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.

BACKGROUND The key to successful neonatal resuscitation is effective ventilation. Little evidence exists to guide clinicians in their choice of manual ventilation device or face mask. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal resuscitation. AIM To compare the efficacy of (a) the Laerdal infant resu...

متن کامل

Face mask ventilation in edentulous patients: a comparison of mandibular groove and lower lip placement.

BACKGROUND In edentulous patients, it may be difficult to perform face mask ventilation because of inadequate seal with air leaks. Our aim was to ascertain whether the "lower lip" face mask placement, as a new face mask ventilation method, is more effective at reducing air leaks than the standard face mask placement. METHODS Forty-nine edentulous patients with inadequate seal and air leak dur...

متن کامل

Comparison of bag-valve-mask hand-sealing techniques in a simulated model.

STUDY OBJECTIVE Bag-valve-mask ventilation remains an essential component of airway management. Rescuers continue to use both traditional 1- or 2-handed mask-face sealing techniques, as well as a newer modified 2-handed technique. We compare the efficacy of 1-handed, 2-handed, and modified 2-handed bag-valve-mask technique. METHODS In this prospective, crossover study, health care providers p...

متن کامل

Optimizing bag-valve-mask ventilation with a new mouth-to-bag resuscitator.

When ventilating an unintubated patient with a self-inflating bag, high peak inspiratory flow rates may result in high peak airway pressure with subsequent stomach inflation; this may occur frequently when rescuers without daily experience in bag-valve-mask ventilation need to perform advanced airway management. The purpose of this study was to assess the effects of a newly developed self-infla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 90 5  شماره 

صفحات  -

تاریخ انتشار 2005