Comparison of speech processing strategies used in the Clarion implant processor.
نویسندگان
چکیده
OBJECTIVE To evaluate the performance of the various speech processing strategies supported by the Clarion S-Series implant processor. DESIGN Five different speech-processing strategies [the Continuous Interleaved Sampler (CIS), the Simultaneous Analog Stimulation (SAS), the Paired Pulsatile Sampler (PPS), the Quadruple Pulsatile Sampler (QPS) and the hybrid (HYB) strategies] were implemented on the Clarion Research Interface platform. These speech-processing strategies varied in the degree of electrode simultaneity, with the SAS strategy being fully simultaneous (all electrodes are stimulated at the same time), the PPS and QPS strategies being partially simultaneous and the CIS strategy being completely sequential. In the hybrid strategy, some electrodes were stimulated using SAS, and some were stimulated using CIS. Nine Clarion CIS users were fitted with the above speech processing strategies and tested on vowel, consonant and word recognition in quiet. RESULTS There were no statistically significant differences in the mean group performance between the CIS and SAS strategies on vowel and sentence recognition. A statistically significant difference was found only on consonant recognition. Individual results, however, indicated that most subjects performed worse with the SAS strategy compared with the CIS strategy on all tests. About 33% of the cochlear implant users benefited from the PPS and QPS strategies on consonant and word recognition. CONCLUSIONS If temporal information were the primary factor in speech recognition with cochlear implants then SAS should consistently produce higher speech recognition scores than CIS. That was not the case, however, because most CIS users performed significantly worse with the SAS strategy on all speech tests. Hence, there seems to be a trade-off between improving the temporal resolution with an increasing number of simultaneous channels and introducing distortions from electrical-field interactions. Performance for some CI users improved when the number of simultaneous channels increased to two (PPS strategy) and four (QPS strategy). The improvement with the PPS and QPS strategies must be due to the higher rates of stimulation. The above results suggest that CIS users are less likely to benefit with the SAS strategy, and they are more likely to benefit from the PPS and QPS strategies, which provide higher rates of stimulation with small probability of channel interaction.
منابع مشابه
SPAIDE: A Real-time Research Platform for the Clarion CII/90K Cochlear Implant
SPAIDE (sound-processing algorithm integrated development environment) is a real-time platform of Advanced Bionics Corporation (Sylmar, Calif, USA) to facilitate advanced research on sound-processing and electrical-stimulation strategies with the Clarion CII and 90K implants. The platform is meant for testing in the laboratory. SPAIDE is conceptually based on a clear separation of the sound-pro...
متن کاملSpeech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants.
Speech recognition was measured as a function of spectral resolution (number of spectral channels) and speech-to-noise ratio in normal-hearing (NH) and cochlear-implant (CI) listeners. Vowel, consonant, word, and sentence recognition were measured in five normal-hearing listeners, ten listeners with the Nucleus-22 cochlear implant, and nine listeners with the Advanced Bionics Clarion cochlear i...
متن کاملUsing a Personal Computer to Perform Real-Time Signal Processing in Cochlear Implant Research
Cochlear implants are electronic devices that have enabled individuals with severe to profound hearing losses to regain some hearing. There is, however, substantial variability in speech perception performance among users of cochlear implants. One factor that may contribute to the individual differences is the way in which the device converts acoustic sound waves into electrical stimulation: th...
متن کاملEffects of presentation level on phoneme and sentence recognition in quiet by cochlear implant listeners.
OBJECTIVE The objectives of this study were to characterize the effects of presentation level on speech recognition in quiet by cochlear implant users with the Nucleus 22 SPEAK and Clarion v1.2 CIS speech-processing strategies, and to relate speech recognition at low presentation levels to stimulus audibility as measured by sound field thresholds. It was hypothesized that speech recognition per...
متن کاملComparison of electrically evoked compound action potential thresholds and loudness estimates for the stimuli used to program the Advanced Bionics cochlear implant.
BACKGROUND In the mid-1990s, Cochlear Corporation introduced a cochlear implant (CI) to the market that was equipped with hardware that made it possible to record electrically evoked compound action potentials (ECAPs) from CI users of all ages. Over the course of the next decade, many studies were published that compared ECAP thresholds with levels used to program the speech processor of the Nu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ear and hearing
دوره 24 1 شماره
صفحات -
تاریخ انتشار 2003