The CA 125 II assay on the Elecsys(R) 2010 analyzer was evaluated in an international multicenter trial. Imprecision studies yielded within-run CVs of 0.8-3.3% and between-day CVs of 2.4-10.9%; CVs for total imprecision in the manufacturer's laboratory were 2.4-7.8%. The linear range of the assay extended to at least 4500 kilounits/L (three decades). Interference from triglycerides (10.3 mmol/L), bilirubin (850 micromol/L), hemoglobin (1.1 mmol/L), anticoagulants (plasma), and several widely used drugs was undetectable. Method comparisons with five other CA 125 II assays showed good correlation but differences in standardization. A 95th percentile cutoff value of 35 kilounits/L was calculated from values measured in 593 apparently healthy (pre- and postmenopausal) women. In 95% of patients with benign gynecological diseases CA 125 was 190 kilounits/L. A comparison of CA 125 values obtained with the Elecsys test and with other common CA 125 tests in monitored patients being treated for ovarian cancer showed identical patterns. In conclusion, the Elecsys CA 125 II assay is linear over a broad range, yields precise and accurate results, is free from interferences, and compares well with other assays.
منابع مشابه
Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125.
A novel strategy for immunoassay and the preparation of reagentless immunosensors was proposed. This strategy was based on the immobilization of antigen and the direct electrochemistry of horseradish peroxidase (HRP) that was labeled to an antibody. A reagentless immunosensor for carcinoma antigen-125 (CA 125) determination was developed. The immunosensor was prepared by immobilizing CA 125 wit...
متن کاملFlow-through multianalyte chemiluminescent immunosensing system with designed substrate zone-resolved technique for sequential detection of tumor markers.
A novel flow-through immunosensing system for performing a multianalyte chemiluminescent determination in a single run was designed. A new analytical strategy of substrate zone-resolved technique was proposed. Using carcinoma antigen 125 (CA 125) and carcinoembryonic antigen (CEA) as model analytes, the capture antibodies for CA 125 and CEA were immobilized on an UltraBind aldehyde-activated me...
متن کاملMonitoring cancer antigen 125 in serum of ovarian cancer patients after administration of 131I-labeled F(ab')2 fragments of OC125 antibody.
We evaluated the effect of repeated administration of OC125 F(ab')2 fragments on cancer antigen (CA) 125 determination in 210 serum samples from 30 patients. We found falsely high CA 125 concentrations in 142 (68%) samples, using a homologous CA 125 enzyme immunoassay (EIA) with OC125 antibodies. The Truquant OV2 method, which involves two other murine antibodies, and the IMx CA 125 method, whi...
متن کاملEvidence for interaction of human anti-idiotypic antibodies with CA 125 determination in a patient after radioimmunodetection.
Very high concentrations of CA 125 have been found in some ovarian cancer patients after repeated radioimmunodetection with anti-CA 125 antibodies [OC125-F(ab')2]. In one patient we measured a CA 125 concentration of 135,000 kilo-arb. units/L, using an enzyme immunoassay involving OC125 antibodies. With an immunoradiometric assay involving use of two new anti-CA 125 antibodies (B43.13 and B27.1...
متن کاملQuartz crystal microbalance immunoassay for carcinoma antigen 125 based on gold nanowire-functionalized biomimetic interface.
Gold nanowires with of designed length on a solid substrate have been proven as an efficiently immobilized affinity support for the detection of carcinoma antigen 125 (CA 125) in this study. The presence of gold nanowires provides a well-defined three-dimensional structure, and greatly amplifies the coverage of the anti-CA 125 protein on the probe surface. Moreover, the amount of anti-CA 125 va...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 44 12 شماره
صفحات -
تاریخ انتشار 1998