Biological false positive serological tests for syphilis in the Jamaican population.

نویسندگان

  • M F Smikle
  • O B James
  • P Prabhakar
چکیده

A total of 19,067 sera were screened for biological false positive (BFP) reactivity by the Venereal Disease Research Laboratory (VDRL) test. Sera which were reactive in the VDRL test were confirmed by the fluorescent treponemal antibody absorption (FTA-ABS) test. BFP reactions were detected in 0.59% of the general population, 0.72% of pregnant women and 11.8% of patients with systemic lupus erythematosus (SLE). The rate of BFP reactors among pregnant women did not differ significantly from the general population. The female to male ratio of BFP in the general population was 2:1 whilst that in the group of patients with SLE was 8:1. The overall seroprevalence of syphilis was 2.2%.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ageing and false positive reactions for syphilis.

Biological false positive reactors for syphilis (BFP) are defined as those patients having reagin demonstrated by positive serological tests for syphilis and non-reactive treponemal antibody tests. Acute biological false-positive reactions (ABFP) terminate in 1 to 6 months. Patients in whom reagin persists longer than 6 months are considered to have chronic reactions (CBFP). Harvey (1962) stres...

متن کامل

Chronic biological false-positive reactions to serological tests for syphilis in blood donors.

Problem sera from 375 blood donors were investigated for biological false-positive reactions to serological tests for syphilis. Problem sera are those sera in which submitting laboratories have found a reactive result to a screening test for syphilis. On each serum a cardiolipin Wassermann reaction, a Venereal Disease Research Laboratory test, a Reiter protein-complement fixation test, a Trepon...

متن کامل

The biological false positive reaction to serological tests for syphilis.

Acute and chronic biological false positive reactions to serological tests for syphilis are discussed. Three cases are presented, one showing an acute and one a chronic reaction, and one in which it was not possible to determine if the reaction was acute or chronic. Once a biological false positive reaction is found, serum from the patient should be tested at intervals for at least six months t...

متن کامل

Non-specific reactions to the quantitative fluorescent antibody test (FTA) in the elderly.

Recently, Carr, Becker, and Carpenter (1966) published evidence indicating that biological false positive reactions to reagin tests, as judged primarily by negative results to the treponemal immobilization test, occurred more frequently in elderly patients than in the population as a whole. Although some aspects of this work have been justifiably criticized by Wuepper and Tuffanelli (1966), the...

متن کامل

Serological tests in 150 cases of leprosy.

Hansen's disease is considered to be one of the well-known infections which upset serological tests for syphilis in patients in whom there has been no past or current treponemal infection. The reason why lepers are biological false positive (B.F.P.) reactors and why this failure in the specificity of lipoidal reactions occurs remains obscure. The frequency of false positive reactions is said to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Genitourinary medicine

دوره 66 2  شماره 

صفحات  -

تاریخ انتشار 1990