VFMA: Topographic Analysis of Sensitivity Data From Full-Field Static Perimetry.
نویسندگان
چکیده
PURPOSE To analyze static visual field sensitivity with topographic models of the hill of vision (HOV), and to characterize several visual function indices derived from the HOV volume. METHODS A software application, Visual Field Modeling and Analysis (VFMA), was developed for static perimetry data visualization and analysis. Three-dimensional HOV models were generated for 16 healthy subjects and 82 retinitis pigmentosa patients. Volumetric visual function indices, which are measures of quantity and comparable regardless of perimeter test pattern, were investigated. Cross-validation, reliability, and cross-sectional analyses were performed to assess this methodology and compare the volumetric indices to conventional mean sensitivity and mean deviation. Floor effects were evaluated by computer simulation. RESULTS Cross-validation yielded an overall R2 of 0.68 and index of agreement of 0.89, which were consistent among subject groups, indicating good accuracy. Volumetric and conventional indices were comparable in terms of test-retest variability and discriminability among subject groups. Simulated floor effects did not negatively impact the repeatability of any index, but large floor changes altered the discriminability for regional volumetric indices. CONCLUSIONS VFMA is an effective tool for clinical and research analyses of static perimetry data. Topographic models of the HOV aid the visualization of field defects, and topographically derived indices quantify the magnitude and extent of visual field sensitivity. TRANSLATIONAL RELEVANCE VFMA assists with the interpretation of visual field data from any perimetric device and any test location pattern. Topographic models and volumetric indices are suitable for diagnosis, monitoring of field loss, patient counseling, and endpoints in therapeutic trials.
منابع مشابه
Structure-Function Modeling of Optical Coherence Tomography and Standard Automated Perimetry in the Retina of Patients with Autosomal Dominant Retinitis Pigmentosa
PURPOSE To assess relationships between structural and functional biomarkers, including new topographic measures of visual field sensitivity, in patients with autosomal dominant retinitis pigmentosa. METHODS Spectral domain optical coherence tomography line scans and hill of vision (HOV) sensitivity surfaces from full-field standard automated perimetry were semi-automatically aligned for 60 e...
متن کاملFascicular Visual Field Defects in Open-Angle Glaucoma: Evaluation with Microperimetry
Purpose. Use of microperimetry (Mp-1), correlating with Humphrey perimetry (30-2 program), in patients affected by primary open-angle glaucoma (POAG) with perimetric defects, in order to obtain an evaluation of the accuracy of the results obtained by Mp-1. Materials and Methods. In this study 40 eyes of 25 patients affected by POAG with perimetric defects were included. All patients underwent m...
متن کاملBehavioral perimetry in monkeys.
PURPOSE Normative data on the systematic changes in visual sensitivity as a function of retinal eccentricity have provided the basis for efficient threshold strategies and data analysis routines for static perimetry. The standard methods of assessing visual field changes in patients also could be used for monkeys with experimentally induced ocular disorders if the normal visual fields of monkey...
متن کاملPerimetry Comparisons for Octopus G Top and Dynamic Programmes versus Humphrey 24-2 SITA Fast and SITA Standard Programmes
Aims: Previous comparisons of Octopus and Humphrey threshold programmes have shown differences, particularly for depth of defects. Recent developments have altered the Octopus background illumination. Thus, we sought to determine the subsequent extent of differences in results from commonly used central static programmes using Octopus and Humphrey perimeters. Study Design: Diagnostic accuracy s...
متن کاملMechanisms mediating visual detection in static perimetry.
PURPOSE The usual stimuli in static perimetry are white-light luminance increments. However, the specific visual detection mechanisms involved in perimetry are unknown because all classes of neural mechanisms are sensitive to spectrally broadband stimuli. The objective of this study was to determine the relative sensitivities of nonopponent and opponent detecting mechanisms under standard perim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Translational vision science & technology
دوره 4 2 شماره
صفحات -
تاریخ انتشار 2015