Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter?

نویسندگان

  • C F Tsai
  • C T Tai
  • W C Yu
  • Y J Chen
  • M H Hsieh
  • C E Chiang
  • Y A Ding
  • M S Chang
  • S A Chen
چکیده

BACKGROUND The prospective, randomized study comparing 4- with 8-mm tip electrodes for radiofrequency linear ablation of typical atrial flutter is not available. METHODS AND RESULTS A total of 104 consecutive patients with typical atrial flutter were randomly assigned to undergo radiofrequency linear ablation using a 4- (Group I, n=54) or 8-mm tip electrode (Group II, n=50) catheter (temperature-control model, preset 70 degrees C). If complete bidirectional isthmus block could not be achieved after 5 pulses, the ablation catheter was changed to the other type; the maximal radiofrequency pulse number was limited to <10 pulses. Complete or incomplete isthmus conduction block was assessed by activation sequence in a multielectrode Halo catheter during low lateral right atrial and proximal coronary sinus pacing. Before shifting to the other catheter type, the 8-mm electrode catheter achieved higher complete isthmus block rate (92% versus 67%, P<0.05) with fewer pulses (2+/-1 versus 3+/-1, P<0.05), shorter procedure time (24+/-15 versus 31+/-12 minutes, P<0.05), and shorter fluoroscopic time (14+/-10 versus 23+/-15 minutes, P<0.05). After 5 failed ablation pulses, 12 (67%) of 18 patients in group I attained complete isthmus block by using an 8-mm tip catheter, but none of 4 patients in group II achieved complete block by changing to a 4-mm tip catheter. CONCLUSIONS The 8-mm tip electrodes are more effective than the standard 4-mm length electrodes in linear ablation for typical atrial flutter. This clinical benefit may be of particular value for some patients with broad and/or thick isthmus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Remote magnetic navigation for ablation of typical atrial flutter: Long-term results.

INTRODUCTION AND AIM Remote magnetic navigation has proved to be effective in the ablation of most supraventricular and ventricular arrhythmias. Initial studies reported worse results with this system compared to conventional ablation for atrial flutter. The aim of this study was to assess the acute and long-term success of atrial flutter ablation with remote magnetic navigation and to retrospe...

متن کامل

Comparison of 8-mm-tip and irrigated-tip catheters in the ablation of isthmus-dependent atrial flutter: a prospective randomized trial.

INTRODUCTION AND OBJECTIVES Both 8-mm-tip and irrigated-tip catheters improve outcomes in typical atrial flutter ablation. However, it is not yet known which is preferable. The objective was to compare the effectiveness of 8-mm-tip (Group 1) and open irrigated-tip (Group 2) catheters in the first ablation attempt. METHODS A prospective randomized trial with a long-term follow-up was performed...

متن کامل

Prospective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter.

BACKGROUND Radiofrequency (RF) ablation of cavotricuspid isthmus (CTI) dependent flutter can be performed using different types of ablation catheters. It has been proposed that irrigated and large-tip catheters are capable of creating larger lesions, resulting in greater efficacy. This prospective, randomised clinical study compared the efficacy of irrigated and large-tip catheters of different...

متن کامل

Flutter ablation with remote magnetic navigation: comparison between the 8-mm tip, the irrigated tip and a manual approach.

INTRODUCTION Remote magnetic navigated ablation has proven its feasibility in a large group of arrhythmias. Until now only scarce data are available on the use for atrial flutter. In this study we compared remote magnetic navigation (RMN), using non-irrigated and irrigated tip catheters, to manual radiofrequency ablation for ablating typical atrial flutter. METHODS The 3 study groups consiste...

متن کامل

Randomized comparison of cavotricuspid isthmus ablation for atrial flutter using an open irrigation-tip versus a large-tip radiofrequency ablation catheter.

BACKGROUND Large-tip (10 mm) catheters (LTCs) and open-irrigation-tip catheters (OITCs), both capable of creating large lesions, are more effective than conventional catheters for cavotricuspid isthmus (CTI) ablation. However, it is not clear whether complete CTI block can be achieved more efficiently using an LTC or an OITC. The purpose of this study was to compare the efficiency of radiofrequ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 100 7  شماره 

صفحات  -