Time-resolved fluorometer for lanthanide chelates--a new generation of nonisotopic immunoassays.

نویسندگان

  • E Soini
  • H Kojola
چکیده

Pulsed-light time-resolved fluorometry of lanthanide chelates has proved to be very sensitive for use with nonisotopic immunoassays. We describe a manually operated fluorometer with a conventional xenon flashtube. Sensitivity for 1-s determinations is similar to that of radioisotopic methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-resolved detection of lanthanide luminescence for ultrasensitive bioanalytical assays.

The principles and practice of the application of time-resolved lanthanide chelate luminescence (or fluorescence) as a detection method for ultrasensitive bioanalytical assays such as immunoassays and nucleic acid hybridization assays are reviewed. The various lanthanide chelate-based detection systems which have been developed for use in heterogeneous and homogeneous assay formats are describe...

متن کامل

Multiple fluorescent labeling of silica nanoparticles with lanthanide chelates for highly sensitive time-resolved immunofluorometric assays.

BACKGROUND Time-resolved immunofluorometric assays (TrIFA) using lanthanide-labeled nanoparticles have greatly increased the sensitivity of immunoassays. Current labeling strategies, however, use either physical doping of lanthanide chelates into preformed nanoparticles or covalent linking of lanthanide chelates to precursors used for making nanoparticles; both these strategies have drawbacks. ...

متن کامل

Encapsulation-Stabilized, Europium Containing Nanoparticle as a Probe for Time-Resolved luminescence Detection of Cardiac Troponin I

The use of a robust optical signaling probe with a high signal-to-noise ratio is important in the development of immunoassays. Lanthanide chelates are a promising material for this purpose, which provide time-resolved luminescence (TRL) due to their large Stokes shift and long luminescence lifetime. From this, they have attracted considerable interest in the in vitro diagnostics field. However,...

متن کامل

Simultaneous quadruple-label fluorometric immunoassay of thyroid-stimulating hormone, 17 alpha-hydroxyprogesterone, immunoreactive trypsin, and creatine kinase MM isoenzyme in dried blood spots.

We describe a quadruple-label fluorometric immunoassay for simultaneously measuring four analytes: thyroid-stimulating hormone (TSH), 17 alpha-hydroxyprogesterone (17 alpha-OHP), immunoreactive trypsin (IRT), and creatine kinase MM (CK-MM). The assay is based on immunoreagents labeled with four different lanthanide ions (Eu3+, Tb3+, Sm3+, and Dy3+), on dissociative fluorescence enhancement appl...

متن کامل

Sensitive bioaffinity assays with individual microparticles and time-resolved fluorometry.

Future immunoassays and nucleic acid hybridization assays will be performed in miniaturized formats that utilize microchips or microparticles. This will require a sensitive detection technology that allows spatial resolution. By using fluorescent europium chelates and time-resolved microfluorometry, one can detect 11,000 europium molecules on individual microparticles. In a miniaturized noncomp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 1983