Use of a new sample-collection device (Macroduct) in anion analysis of human sweat.

نویسندگان

  • D E Cole
  • M J Boucher
چکیده

We compared concentrations of chloride and sulfate in sweat obtained by use of the Macroduct capillary-coil collection device with results obtained by the conventional absorbent filter pad technique. Samples obtained with the device weighed less than those obtained conventionally, but sweat chloride concentrations were not significantly different. To assess analysis of trace anions, we used inorganic sulfate as a prototype. Background contamination, a problem with the filter pads, was negligible with the Macroduct collector. However, with the Macroduct device, sulfate concentrations were nominally higher than with the conventional pads (105 +/- 6 vs 88 +/- 5 mumol/L) and showed no dependence of sulfate concentration on sweat rate. Subtraction of the significant "background" SO4 concentration obtained with blanks (i.e., unused filter pads) is a likely source of error in the conventional method. We consider the Macroduct device useful for study of trace constituents of human sweat.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anion-exchange chromatography to determine the concentration of chloride in sweat for diagnosis of cystic fibrosis.

For the diagnosis of cystic fibrosis, we use the "Macroduct Sweat Collection System" (Wescor) to sample sweat, and anion-exchange chromatography to determine its chloride content. The chromatographic system consists of a Whatman Partisil SAX 10-microns column, an isocratic phosphate-buffered mobile phase, and ultraviolet detection at 200 nm. The sweat chloride concentrations of 10 individuals w...

متن کامل

Sweat testing practice in Swiss hospitals.

AIMS To determine whether the current practice of sweat testing in Swiss hospitals is consistent with the current international guidelines. METHODS A questionnaire was mailed to all children's hospitals (n = 8), regional paediatric sections of general hospitals (n = 28), and all adult pulmonology centres (n = 8) in Switzerland which care for patients with cystic fibrosis (CF). The results wer...

متن کامل

Inconsistencies in sweat testing in UK laboratories.

BACKGROUND Sweat testing procedures are perceived to vary widely. AIM To evaluate variability in sweat collection, analysis, and interpretation. METHODS Questionnaire responses from 30 self selected centres: 15 paediatric centres, and 15 district general hospitals. RESULTS Centres carried out 30-400 tests per year (median 100), with a diagnostic rate of 1:5-152 (median 1:30). Staff perfor...

متن کامل

[Comparison of conductivity with sodium determination in the same sweat sample]

OBJECTIVE: To correlate sweat conductivity by Wescor with quantitative sodium determination in the same sample. METHODS: We analyzed 206 sweat samples, being 31 obtained from patients with cystic fibrosis (CF). Sweat was collected by quantitative pilocarpine iontophoresis in the Macroduct system for 30 minutes. Samples were immediately determined by Sweat-Chek analyzer (Wescor) and sodium quant...

متن کامل

hypoventilation syndrome Previously undiagnosed obesity

The European Diagnostic Working Group presented comprehensive diagnostic algorithms for cystic fibrosis (CF) and confirmed the fundamental role of the sweat test for the diagnosis of CF. However, several important differences between well-accepted guidelines for sweat testing 3 and the recommendations of the Working Group need to be discussed. An adequate sweat sampling volume depends on the sa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 32 7  شماره 

صفحات  -

تاریخ انتشار 1986