Vernier acuity, crowding and cortical magnification.
نویسندگان
چکیده
When a vernier target is flanked by optimally positioned lines, foveal vernier discrimination is strongly degraded (Westheimer and Hauske, 1975). We confirmed this observation (Experiment I) and have mapped out a 2 dimensional "perceptive field" for crowding in the fovea using a 2 dot target (Experiment II). Crowding was also measured in peripheral vision, using either small flanking dots as masks (Experiment III), or using repetitive vernier gratings (Experiment IV). The results showed that when scaled in proportion to recent estimates of the cortical magnification factor, vernier acuity is as good in the periphery as it is centrally. Both centrally and peripherally, there appears to be a psychophysical processing module which we term a "perceptive hypercolumn". At all eccentricities vernier thresholds were found to be approximately 1/40 of the size of a perceptive hypercolumn and were elevated if interfering contours are present in the same (or adjacent) hypercolumns.
منابع مشابه
Cortical Magnification within Human Primary Visual Cortex Correlates with Acuity Thresholds
We measured linear cortical magnification factors in V1 with fMRI, and we measured visual acuity (Vernier and grating) in the same observers. The cortical representation of both Vernier and grating acuity thresholds in V1 was found to be roughly constant across all eccentricities. We also found a within-observer correlation between cortical magnification and Vernier acuity, further supporting c...
متن کاملCortical sources of Vernier acuity in the human visual system: An EEG-source imaging study
Vernier acuity determines the relative position of visual features with a precision better than the sampling resolution of cone receptors in the retina. Because Vernier displacement is thought to be mediated by orientation-tuned mechanisms, Vernier acuity is presumed to be processed in striate visual cortex (V1). However, there is considerable evidence suggesting that Vernier acuity is dependen...
متن کاملVernier Acuity with Non-simultaneous Targets: The Cortical Magnification Factor Estimated by Psychophysics
The eccentricity at which peripheral thresholds double their foveal value (E2) may relate to the visual system's anatomical organization. Using a variety of experimental approaches, previous estimates of E2 for vernier acuity have ranged from less than 0.1 deg to greater than 15.0 deg. This broad range of values seems to challenge the usefulness of E2 for determining visual topography. We expla...
متن کاملDifferences in vernier discrimination for grating between strabismic and anisometropic amblyopes.
Two gratings composed of lines were displayed one above the other, and the vernier threshold was measured as a function of spatial frequency and vertical separation between gratings for 12 strabismic and/or anisometropic amblyopes. The vernier acuity of the anisometropic amblyopes was similar to that of nonamblyopic eyes when scaled proportionally to their reduced grating acuity. Strabismic amb...
متن کاملVernier acuity, crowding and amblyopia.
When a vernier target is flanked by a pair of optimally positioned flanks, offset discrimination is strongly degraded. Spatial interference with vernier acuity was studied in each eye of observers with unilateral amblyopia associated with strabismus, anisometropia or both, and were compared to the functions obtained in the normal periphery (Levi et al., 1985). The results showed that: (1) For b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision research
دوره 25 7 شماره
صفحات -
تاریخ انتشار 1985