Mycobacterial cross contamination during radiometric culturing.

نویسندگان

  • A M Vannier
  • J J Tarrand
  • P R Murray
چکیده

Pseudobacteremias in blood cultures performed on the BACTEC radiometric blood culture system have been reported. We report three cases of cross contamination with Mycobacterium avium that occurred when mycobacteria were cultured with the BACTEC 460 TB system. Malfunction of the needle sterilization heating block was demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mycobacterial growth and bacterial contamination in the mycobacteria growth indicator tube and BACTEC 460 culture systems.

The BACTEC 460 system currently provides the most rapid detection of mycobacterial growth, but the system is radiometric and requires needles to inoculate specimens through the bottle's septum. The Mycobacteria Growth Indicator Tube (MGIT) system has a liquid medium, like the BACTEC system, and does not require needles when inoculating specimens. We compared mycobacterial growth from 510 specim...

متن کامل

Blood culture cross contamination associated with a radiometric analyzer.

During a 9-day period in August 1980 in a New Jersey hospital, three pairs of consecutively numbered blood cultures from different patients were identified as positive for the same organism (two pairs of Klebsiella pneumoniae and one pair of group A Streptococcus), for each pair, both cultures were positive in the same atmosphere, both organisms had the same sensitivities, and the second of eac...

متن کامل

Rapid detection of mycobacteria in clinical specimens by using the automated BACTEC 9000 MB system and comparison with radiometric and solid-culture systems.

Recovery rates of acid-fast bacilli (AFB) and the mean time to their detection from clinical specimens were determined by using the fluorescent BACTEC 9000 MB system. Data were compared to those assessed by the radiometric BACTEC 460 system and by cultivation on solid media. A total of 3,095 specimens were processed with N-acetyl-L-cysteine-NaOH by two laboratories. The contamination rates for ...

متن کامل

Radiometric detection of bacteremia in neonates.

The predicted prevalence of false positive blood cultures due to hyperactive neonatal blood cells in a radiometric detection system was confirmed. Suppression of this blood background radioactivity in the system was achieved by using a hypertonic medium containing 10% sucrose. The radiometric system produced accurate results as fast as the conventional blood culturing method, saved labor and mi...

متن کامل

Infrequent MODS TB culture cross-contamination in a high-burden resource-poor setting.

One obstacle to wider use of rapid liquid culture-based tuberculosis diagnostics such as the microscopic observation drug susceptibility (MODS) assay is concern about cross-contamination. We investigated the rate of laboratory cross-contamination in MODS, automated MBBacT, and Lowenstein-Jensen (LJ) cultures performed in parallel, through triangulation of microbiologic (reculturing stored sampl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 26 9  شماره 

صفحات  -

تاریخ انتشار 1988