Quantitative interpretation of magnetization transfer in spoiled gradient echo MRI sequences.
نویسندگان
چکیده
A method for analyzing general pulsed magnetization transfer (MT) experiments in which off-resonance saturation pulses are interleaved with on-resonance excitation pulses is presented. We apply this method to develop a steady-state signal equation for MT-weighted spoiled gradient echo sequences and consider approximations that facilitate its rapid computation. Using this equation, we assess various experimental designs for quantitatively imaging the fractional size of the restricted pool, cross-relaxation rate, and T(1) and T(2) relaxation times of the two pools in a binary spin bath system. From experiments on agar gel, this method is shown to reliably and accurately estimate the exchange and relaxation properties of a material in an imaging context, suggesting the feasibility of using this technique in vivo.
منابع مشابه
High Resolution Multispectral qMRI Protocol: PD, T1, T2, T2*, ADC, MT
We implemented a dual sequence version of the mixed-TSE sequence, termed here as tandem-mixed-TSE with the following parameters: pulse sequence 1, dual-echo RARE: TE1=14ms, TE2=27ms, TR=4000; pulse sequence 2, dual-echo RARE with inversion recovery pulse: TE1=14ms, TE2=27ms, TI=400ms, TR=4400ms (Figure 1) (1). Images acquired with these two sequences were used to calculate parametric PD, T1, an...
متن کاملFree-breathing 3D cardiac function with accelerated magnetization transfer prepared imaging
Background 3D cardiac MRI has long held promise for improved heart coverage, higher resolution, and reduced sensitivity to poor breath-hold reproducibility. However, its use has been limited by reduced blood pool to myocardium contrast for spoiled and balanced steady-state free precession (bSSFP) implementations. T2-preparation techniques [1] are capable of increasing contrast but are unfortuna...
متن کاملBloch Equation Simulations for bSSFP, Spin Echo, and SPGR Sequences When Using Hyperpolarized Carbon-13
Introduction: Pulse sequence design for the imaging of hyperpolarized nuclei is extremely important because of the short time span available to image due to the rapid decay to thermal equilibrium of hyperpolarized nuclei. Spoiled gradient echo sequences (SPGR) have been used for C spectroscopic imaging [1] because of their relative simplicity, robustness, and multi-spectral performance. However...
متن کاملElimination of Inflow Enhancement by Partial Pre-Saturation in RF Spoiled Imaging
Introduction: For RF-spoiled gradient echo imaging (ie SPGR, FLASH, T1-FFE), the combination of spoiling gradients and quadratic phase cycling eliminates net transverse magnetization within a voxel [1-4] to enable pure T1 contrast. Generally, many RF excitations are required to attain steady state magnetization levels. Therefore, when unsaturated spins are flowing into the imaging volume, inflo...
متن کاملOptimal Flip Angle Set in Spoiled Gradient-Echo MR Imaging Technique
Introduction: In dynmiac contrast enchanted-MRI (DCE-MRI), T1-Weghited spoiled Gradient-Echo (SPGR) sequences are utilized to monitor the distribution of the paramagnetically labeled CAs (contrast agent) in cerebral tumors due to high temporal and spatial resolution [1]. The tissue concentration of CAs measured by CAs effects on the longitudinal relaxation rate of water protons R1 is used by tr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance
دوره 145 1 شماره
صفحات -
تاریخ انتشار 2000