Experimental study of hybrid-knife endoscopic submucosal dissection (ESD) versus standard ESD in a Western country.
نویسندگان
چکیده
BACKGROUND Endoscopic submucosal dissection (ESD) is an effective but time-consuming treatment for early neoplasia that requires a high level of expertise. OBJECTIVE The objective of this study was to assess the efficacy and learning curve of gastric ESD with a hybrid knife with high pressure water jet and to compare with standard ESD. MATERIAL AND METHODS We performed a prospective non survival animal study comparing hybrid-knife and standard gastric ESD. Variables recorded were: Number of en-bloc ESD, number of ESD with all marks included (R0), size of specimens, time and speed of dissection and adverse events. Ten endoscopists performed a total of 50 gastric ESD (30 hybrid-knife and 20 standard). RESULTS Forty-six (92 %) ESD were en-bloc and 25 (50 %) R0 (hybrid-knife: n = 13, 44 %; standard: n = 16, 80 %; p = 0.04). Hybrid-knife ESD was faster than standard (time: 44.6 +/- 21.4 minutes vs. 68.7 +/- 33.5 minutes; p = 0.009 and velocity: 20.8 +/- 9.2 mm(2)/min vs. 14.3 +/- 9.3 mm(2)/min (p = 0.079). Adverse events were not different. There was no change in speed with any of two techniques (hybrid-knife: From 20.33 +/- 15.68 to 28.18 +/- 20.07 mm(2)/min; p = 0.615 and standard: From 6.4 +/- 0.3 to 19.48 +/- 19.21 mm(2)/min; p = 0.607). The learning curve showed a significant improvement in R0 rate in the hybrid-knife group (from 30 % to 100 %). CONCLUSION despite the initial performance of hybrid-knife ESD is worse than standard ESD, the learning curve with hybrid knife ESD is short and is associated with a rapid improvement. The introduction of new tools to facilitate ESD should be implemented with caution in order to avoid a negative impact on the results.
منابع مشابه
Usefulness of a multifunctional snare designed for colorectal hybrid endoscopic submucosal dissection (with video)
Since colorectal endoscopic submucosal dissection (ESD) remains technically difficult, hybrid ESD was developed as an alternative therapeutic option to achieve en bloc resection of relatively large lesions. In this feasibility study, we evaluated the safety and efficacy of hybrid colorectal ESD using a newly developed multifunctional snare. From June to August 2016, we prospectively enrolled 10...
متن کاملTwo electrosurgical endo-knives for endoscopic submucosal dissection of colorectal superficial neoplasms: a prospective randomized study
BACKGROUND AND STUDY AIMS Few studies have directly compared endo-knives for endoscopic submucosal dissection (ESD) in humans. We compared the performances of the Mucosectom2 and SB knife Jr. PATIENTS AND METHODS Two trainee endoscopists performed ESD of 36 lesions in this prospective, randomized controlled trial. Mucosal incision with a 1.5-mm Dual knife and submucosal dissection using the...
متن کاملEfficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection
BACKGROUNDS With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a...
متن کاملEsophageal Endoscopic Submucosal Dissection Assisted by an Overtube with a Traction Forceps: An Animal Study
Esophageal endoscopic submucosal dissection (ESD) is technically difficult. To make it safer, we developed a novel method using overtube with a traction forceps (OTF) for countertraction during submucosal dissection. We conducted an ex vivo animal study and compared the clinical outcomes between OTF-ESD and conventional method (C-ESD). A total of 32 esophageal ESD procedures were performed by f...
متن کاملEvaluation of endoscopic submucosal dissection using a new endosurgical knife DN-D2718B: a first clinical feasibility study
BACKGROUND AND STUDY AIMS Endosurgical devices with injection function have been reported to decrease endoscopic submucosal dissection (ESD) operation times for experts, but the efficacy of these devices for inexperienced endoscopists is unclear. The aim of this study was to evaluate the feasibility of ESD using a novel ESD knife (DN-D2718B). PATIENTS AND METHODS This is a single-center pro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de enfermedades digestivas : organo oficial de la Sociedad Espanola de Patologia Digestiva
دوره 106 2 شماره
صفحات -
تاریخ انتشار 2014