The influence of sweating on the heat transmission properties of cold protective clothing studied with a sweating thermal manikin.

نویسندگان

  • Harriet Meinander
  • Mari Hellsten
چکیده

One of the objectives of the European SUBZERO project was to study the influence of sweat evaporation and condensation on the heat transmission properties of cold protective clothing. With the sweating thermal manikin Coppelius, water vapour transfer through and water condensation in the clothing can be determined simultaneously with the thermal insulation. In this study, 4 cold protective ensembles, intended for use temperatures between 0 and -50 degrees C, were measured with the dry manikin and at 2 different sweating rates. In addition, the ensembles were measured with non-sweating thermal manikins and in wear trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurements of clothing evaporative resistance using a sweating thermal manikin: an overview

Evaporative resistance has been widely used to describe the evaporative heat transfer property of clothing. It is also a critical variable in heat stress models for predicting human physiological responses in various environmental conditions. At present, sweating thermal manikins provide a fast and cost-effective way to determine clothing evaporative resistance. Unfortunately, the measurement r...

متن کامل

Thermal Manikin Evaluation of Liquid Cooling Garments Intended for Use in Hazardous Waste Management

Thermal manikins are valuable tools for quantitatively evaluating the performance of protective clothing ensembles and microclimate cooling systems. The goal of this investigation was to examine the performance of Coretech personal cooling systems, designed to reduce the effects of physiological and environmental heat stress, using a sweating thermal manikin. A sweating manikin takes into accou...

متن کامل

Thermal Manikins and Modelling Edited by Jintu Fan The Hong Kong Polytechnic University Hong Kong

The first standards based on thermal manikin measurements were developed in the1980s. In the Nordic countries tests for thermal insulation measurements of sleepingbags and cold protective clothing were developed. Similar standards were publishedin Germany by DIN and in the US by ASTM. At a European level, EN 342describes test methods and requirements for cold protective clothing...

متن کامل

Development of a two-layer movable sweating thermal manikin.

A thermal manikin is a useful tool to evaluate thermal environments such as clothing, houses and others. A manikin needs to have the following properties: shape and size, heat production, skin temperature, sweat rate, physiological responses and others. So far, no manikin satisfying all these criteria has been available. In the present study, a two-layer movable sweating thermal manikin was new...

متن کامل

Simulation of perspiration in sweating fabric manikin-Walter

Thermal manikins are essential tools for the comfort evaluation of the thermal environment and clothing as well as research into the dynamics of heat and moisture transfer from the human body to the environment – a foundation for thermal physiology and environmental engineering. Since the development of the first non-sweating, single segment copper thermal manikin by the US Army in 1940s, there...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of occupational safety and ergonomics : JOSE

دوره 10 3  شماره 

صفحات  -

تاریخ انتشار 2004