Using Doppler shift induced by Galvanometric mirror scanning to reach shot noise limit with laser optical feedback imaging setup.

نویسندگان

  • O Jacquin
  • E Lacot
  • O Hugon
  • H Guillet de Chatelus
چکیده

This paper proposes what we believe is a new method to remove the contribution of parasitic reflections in the images of the laser optical feedback imaging (LOFI) technique. This simple method allows us to extend the LOFI technique to long-distance applications, as imaging through a fog or a smoke. The LOFI technique is an ultrasensitive imaging technique that is interesting for imaging objects through a scattering medium. However, the LOFI sensitivity can be dramatically limited by parasitic optical feedback occurring in the experimental setup. In previous papers [Appl. Opt.48, 64 (2009)10.1364/AO.48.000064APOPAI1559-128X, Opt. Lett.37, 2514 (2012)10.1364/OL.37.002514OPLEDP0146-9592], we already have proposed methods to filter a parasitic optical feedback, but they are not well suited to metric working distances. This new method uses a Doppler frequency shift induced by the moving mirror used to scan the object to be imaged. Using this Doppler frequency shift, we can distinguish the photons reflected by the target and the parasitic photons reflected by the optical components in the experimental setup. In this paper, we demonstrated theoretically and experimentally the possibility to filter the parasitic reflection in LOFI images using the Doppler frequency shift. This method significantly improves the signal-to-noise ratio by a factor 15 and we can obtain a shot noise limited image through a scattering medium of an object at 3 m from the detector.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synthetic aperture laser optical feedback imaging using a translational scanning with galvanometric mirrors.

In this paper we present an experimental setup based on laser optical feedback imaging (LOFI) and on synthetic aperture with translational scanning by galvanometric mirrors for the purpose of making deep and resolved images through scattering media. We provide real two-dimensional optical synthetic aperture image of a fixed scattering target with a moving aperture and an isotropic resolution. W...

متن کامل

Coherent microscopy by laser optical feedback imaging (LOFI) technique.

The application of the non-conventional imaging technique LOFI (laser optical feedback imaging) to coherent microscopy is presented. This simple and efficient technique using frequency-shifted optical feedback needs the sample to be scanned in order to obtain an image. The effects on magnitude and phase signals such as vignetting and field curvature occasioned by the scanning with galvanometric...

متن کامل

Image distortion and its correction in linear galvanometric mirrors-based laser-scanning microscopy.

To simplify imaging focusing and calibration tasks, a laser-scanning microscope needs to scan ata moderate frame rate. The inertia of a galvanometric scanner leads to time delays when following external commands, which subsequently introduces image distortions that deteriorate as scan frequency increases. Sinusoidal and triangular waveforms were examined as fast axis driving patterns. The inter...

متن کامل

Comparative study of autodyne and heterodyne laser interferometry for imaging.

For given laser output power, object under investigation, and photodiode noise level, we have theoretically compared the signal-to-noise ratios of a heterodyne scanning imager based on a Michelson interferometer and of an autodyne setup based on the laser optical feedback imaging (LOFI) technique. In both cases, the image is obtained point by point. In the heterodyne configuration, the beating ...

متن کامل

A Mathematical Model and Calibration Procedure for Galvanometric Laser Scanning Systems

Laser galvanometric scanning systems are commonly used in various fields such as three dimensional scanning, medical imaging, material processing, measurement devices and laser display systems. The systems of such kind suffer from distortions. On top of that they do not have a center of projection, which makes it impossible to use common projector calibration procedures. The paper presents a no...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 54 8  شماره 

صفحات  -

تاریخ انتشار 2015