Real-time imaging of epileptic seizures in rats using electrical impedance tomography
نویسندگان
چکیده
The presence of multiple or diffuse lesions on imaging is a contraindication to surgery for patients with intractable epilepsy. Theoretically, as a functional imaging technique, electrical impedance tomography (EIT) can accurately image epileptic foci. However, most current studies are limited to examining epileptic spikes and few studies use EIT for real-time imaging of seizure activity. Moreover, little is known about changes in electrical impedance during seizures. In this study, we used EIT to monitor seizure progression in real time and analyzed changes in electrical impedance during seizures. EIT and electroencephalography data were recorded simultaneously in rats. Sixty-three seizures were recorded from the cortices of eight rats. During 54 seizures, the average impedance decreased by between 4.86 and 9.17% compared with the baseline. Compared with the control group, the average impedance of the experimental group decreased significantly (P=0.004). Our results indicate that EIT can be used to detect and image electrical impedance reduction within lesions during epileptic seizures.
منابع مشابه
Applications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملA feasibility study for imaging of epileptic seizures by EIT using a realistic FEM of the head
Electrical Impedance Tomography could be used to image the source of epileptic seizures, by measuring voltages on the scalp due to internal brain conductivity changes. The purpose of this study was to model the magnitude of the boundary voltage changes resulting from focal seizures at 7 frequencies from 5 Hz-4MHz, using a realistic 3D finite element model of the human head and 31 scalp electrod...
متن کاملDetermination of optimal parameters and feasibility for imaging epileptic seizures by Electrical Impedance Tomography
Electrical Impedance Tomography (EIT) may potentially provide a novel noninvasive method for imaging the sources of epileptic seizures, but so far initial clinical studies were unsuccessful, as baseline noise obscured any signal. The purpose of this study was to guideline specification for improved recording equipment, by estimating signal magnitude in relation to noise and the optimal frequenc...
متن کاملA first pilot study of Electrical Impedance Tomography with scalp electrodes during epileptic seizures in humans
Electrical Impedance Tomography (EIT) has the potential to produce images during epileptic seizures. This would improve the accuracy of the localization of epileptic foci in patients undergoing presurgical assessment for curative neurosurgery. It has already been shown that impedance increases by up to 22% during induced epileptic seizures in animal models, using cortical or implanted electrode...
متن کاملDetermination of Optimal Parameters and Feasibility for Imaging of Epileptic Seizures by Electrical Impedance Tomography: A Modelling Study Using a Realistic Finite Element Model of the Head
One potentially powerful application of Electrical Impedance Tomography (EIT) lies in the detection of the source of epileptic seizures in the brain (Holder, 2005). Many patients with epilepsy can be treated with drugs, but surgical resection of the abnormal region which produces seizures may be the only option in severe cases (Engel, Jr., 1993; Rosenow and Luders, 2001). For these, EIT could b...
متن کامل