Quantitative, fluorogenic probe PCR assay for detection of human herpesvirus 8 DNA in clinical specimens.
نویسندگان
چکیده
A quantitative, fluorescence-based PCR assay (TaqMan-based system) was developed for detection of human herpesvirus 8 (HHV-8) DNA in clinical specimens. Primers and probes chosen from each of five 10-kb segments from the unique region of the HHV-8 genome were evaluated for sensitivity with dilution series of DNA extracted from a cell line (BCBL-1) that harbors HHV-8 DNA. Although several of the primer-probe sets performed similarly with BCBL-1 DNA that had been diluted in water, their performance differed when target DNA was diluted in a constant background of uninfected cell DNA, an environment more relevant to their intended use. The two best primer-probe combinations were specific for HHV-8 relative to the other known human herpesviruses and herpesvirus saimiri, a closely related gammaherpesvirus of nonhuman primates. PCRs included an enzymatic digestion step to eliminate PCR carryover and an exogenous internal positive control that enabled discrimination of false-negative from true-negative reactions. The new assays were compared to conventional PCR assays for clinical specimens (saliva, rectal brushings, rectal swab specimens, peripheral blood lymphocytes, semen, and urine) from human immunodeficiency virus-positive patients with or without Kaposi's sarcoma. In all instances, the new assays agreed with each other and with the conventional PCR system. In addition, the quantitative results obtained with the new assays were in good agreement both for duplicate reactions in the same assay and between assays.
منابع مشابه
Rapid detection of enterovirus RNA in cerebrospinal fluid specimens with a novel single-tube real-time reverse transcription-PCR assay.
A single-tube real-time reverse transcription-PCR (RT-PCR) assay for enterovirus detection in cerebrospinal fluid (CSF) was developed based on a fluorogenic probe and primers directed to highly conserved sequences in the 5' untranslated region of the enterovirus genome. Quantitative detection of enterovirus genome was demonstrated in a linear range spanning at least 5 logs. Endpoint titration e...
متن کاملEpstein-Barr Virus and Human Herpesvirus 8 in Idiopathic Pulmonary Fibrosis
Background & Objective: Idiopathic pulmonary fibrosis (IPF) is a chronic and uniformly fatal interstitial lung disease with incompletely understood pathogenesis. Several studies have given the evidence for and against viral cofactors in the pathogenesis of Idiopathic pulmonary fibrosis. In this study Epstein-Bar Virus (EBV) and Human Herpesvirus 8 (HH...
متن کاملCalibrated real-time PCR assay for quantitation of human herpesvirus 8 DNA in biological fluids.
Accurate laboratory tests for the diagnosis of active human herpesvirus 8 (HHV-8) infection are becoming essential to study the pathogenesis of HHV-8-associated tumors and for the clinical management of HHV-8-infected individuals. We have developed a highly sensitive, calibrated quantitative real-time PCR assay for the measurement of cell-free HHV-8 DNA in body fluids, based on the addition of ...
متن کاملOptimization of PCR-ELISA in Detection of Human Cytomegalovirus Infection
Abstract Background and Objective: Human Cytomegalovirus (CMV) is an important cause of congenital viral infection that can lead to serious diseases and complications in infants. Application of rapid, sensitive, and specific HCMV detection methods is necessary for congenital infection detection. We aimed to optimize the use of PCR and ELISA for detection of HCMV in infants. Material and Methods...
متن کاملDevelopment of a Sensitive Quantitative Competitive PCR Assay for Detection of Human Cytomegalovirus DNA
Accurate and rapid diagnosis of human cytomegalovirus (HCMV) disease in immunocompromised patients has remained as a challenge. Quantitative competitive PCR (QC-PCR) methods for detection of HCMV in these individuals have improved the positive and negative predictive values of PCR for diagnosis of HCMV disease. In this study we used QC-PCR assay, using a co-amplified DNA standard, to quantitate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 39 10 شماره
صفحات -
تاریخ انتشار 2001