Degeneracies at a β-Beam and a Super-Beam Facility
نویسنده
چکیده
The presence of degeneracies can considerably worsen the measure of the neutrino oscillation parameters θ13 and δ. We study the physics reach of a specific “CERN” setup, using a standard β-Beam and Super-Beam facility. These facilities have a similar sensitivity in both parameters. Their combination does not provide any dramatic improvement as expected due to their almost identical L/E ratio. We analyse if adding the correspondent disappearance channels can help in reducing the effect of degeneracies in the (θ13, δ) measure.
منابع مشابه
International Scoping Study ( ISS ) for a future neutrino factory and Super - Beam facility . Detectors and flux instrumentation for future neutrino facilities
This report summarises the conclusions from the detector group of the International Scoping Study of a future Neutrino Factory and Super-Beam neutrino facility. The baseline detector options for each possible neutrino beam are defined as follows: 1. A very massive (Megaton) water Cherenkov detector is the baseline option for a sub-GeV Beta Beam and Super Beam facility. 2. There are a number of ...
متن کاملStudy of the eightfold degeneracy with a standard β-Beam and a Super-Beam facility
The study of the eightfold degeneracy at a neutrino complex that includes a standard β-Beam and a Super-Beam facility is presented for the first time in this paper. The scenario where the neutrinos are sent toward a Megaton water Cerenkov detector located at the Fréjus laboratory (baseline 130 Km) is exploited. The performance in terms of sensitivity for measuring the continuous (θ13 and δ) and...
متن کاملAppearance and disappearance signals at a β-Beam and a Super-Beam facility
In this letter we present the study of the eightfold degeneracy in the (θ13, δ) measurement including both appearance and disappearance channels. We analyse, for definiteness, the case of a standard low-γ β-Beam and a 4 MWatt SPL Super-Beam facility, both aiming at a UNO-like Mton water Čerenkov detector located at the Fréjus laboratory, L = 130 km. In the β-Beam case, the νe disappearance chan...
متن کاملطراحی شبکه برای حلقه انبارش چشمه نور ایران
The Iranian Light Source Facility (ILSF) as a national project is a 3 GeV third generation synchrotron light source facility which provides high energy super bright X-ray for the users. Design of the ILSF storage ring emphasizes an ultra low electron beam emittance (below than 5 nm.rad), beam current of 400 mA, great brightness, stability and reliability which make it competitive in the operati...
متن کاملStudy of Dosimetric Properties of Flattening Filter Free Photon Beam Passing through Cadmium Free Compensator Alloy
Background: This study aims to investigate radiation beam geometry of Cyberknife beam and change in dosimetric characteristics of six megavoltage (6MV) flattening filter free (FFF) beam after passing through high density cadmium free compensator alloy.Material and Methods: In this experimental study, changes in FFF beam dosimetric characteristics after passing through compensator alloy wa...
متن کامل