Influence of different interfaces on synchrony during pressure support ventilation in a pediatric setting: a bench study.

نویسندگان

  • Giorgio Conti
  • Cesare Gregoretti
  • Giorgia Spinazzola
  • Olimpia Festa
  • Giuliano Ferrone
  • Flora Cipriani
  • Marco Rossi
  • Marco Piastra
  • Roberta Costa
چکیده

BACKGROUND In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive respiratory conditions. METHODS A test lung, connected to a pediatric mannequin using different interfaces (endotracheal tube [ETT], face mask, and helmet), was ventilated in pressure support ventilation mode testing 2 ventilator settings (pressurization time [Timepress]50%/cycling-off flow threshold [Trexp]25%, Timepress80%/Trexp60%), randomly applied. The test lung was set to simulate one pediatric patient with a healthy respiratory system and another with a mixed obstructive and restricted respiratory condition, at different breathing frequencies (f) (30, 40, and 50 breaths/min). We measured inspiratory trigger delay, pressurization time, expiratory trigger delay, and time of synchrony. RESULTS At each breathing frequency, the helmet showed the longest inspiratory trigger delay compared with the ETT and face mask. At f30, the ETT had a reduced Tpress. The helmet had the shortest Tpress in the simulated child with a mixed obstructive and restricted respiratory condition, at f40 during Timepress50%/Trexp25% and at f50 during Timepress80%/Trexp60%. In the simulated child with a normal respiratory condition, the ETT presented the shortest Tpress value at f50 during Timepress80%/Trexp60%. Concerning the expiratory trigger delay, the helmet showed the best interaction at f30, but the worst at f40 and at f50. The helmet showed the shortest time of synchrony during all ventilator settings. CONCLUSIONS The choice of the interface can influence patient-ventilator synchrony in a pediatric model breathing at increased f, thus making it more difficult to set the ventilator, particularly during noninvasive ventilation. The helmet demonstrated the worst interaction, suggesting that the face mask should be considered as the first choice for delivering noninvasive ventilation in a pediatric model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of an automatic triggering and cycling system on comfort and patient-ventilator synchrony during pressure support ventilation.

BACKGROUND The digital Auto-Trak™ system is a technology capable of automatically adjusting the triggering and cycling mechanisms during pressure support ventilation (PSV). OBJECTIVE To compare Auto-Trak with conventional settings in terms of patient-ventilator synchrony and discomfort. METHODS Twelve healthy volunteers underwent PSV via the mouth by breathing through an endotracheal tube. ...

متن کامل

A prospective crossover comparison of neurally adjusted ventilatory assist and pressure-support ventilation in a pediatric and neonatal intensive care unit population.

OBJECTIVE To compare neurally adjusted ventilatory assist ventilation with pressure-support ventilation. DESIGN Prospective, crossover comparison study. SETTING Tertiary care pediatric and neonatal intensive care unit. PATIENTS Sixteen ventilated infants and children: mean age = 9.7 months (range = 2 days-4 yrs) and mean weight = 6.2 kg (range = 2.4-13.7kg). INTERVENTIONS A modified nas...

متن کامل

A bench study of 2 ventilator circuits during helmet noninvasive ventilation.

OBJECTIVE To compare helmet noninvasive ventilation (NIV), in terms of patient-ventilator interaction and performance, using 2 different circuits for connection: a double tube circuit (with one inspiratory and one expiratory line) and a standard circuit (a Y-piece connected only to one side of the helmet, closing the other side). METHODS A manikin, connected to a test lung set at 2 breathing ...

متن کامل

Comparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery

Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...

متن کامل

Spontaneous Breathing Trial a Reliable Method for Weaning in Children

Introduction  Mechanical ventilation may be lifesaving intervention,It can be associated with complications,Thus,successful weaning is constitutive.One of the factors which is  important in successful weaning is  method of weaning. It is shown that  weaning is conducted successfully by using Spontaneous Breathing Trial (SBT) through T-piece and pressure support (PS) ventilation.But few studies ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 60 4  شماره 

صفحات  -

تاریخ انتشار 2015