The influence of clearance on friction, lubrication and squeaking in large diameter metal-on-metal hip replacements.

نویسندگان

  • Claire L Brockett
  • Phil Harper
  • Sophie Williams
  • Graham H Isaac
  • Rob S Dwyer-Joyce
  • Zhongmin Jin
  • John Fisher
چکیده

Large diameter metal-on-metal bearings (MOM) are becoming increasingly popular, addressing the needs of young and more active patients. Clinical data has shown excellent short-to-mid-term results, though incidences of transient squeaking have been noted between implantation and up to 2 years post-operative. Geometric design features, such as clearance, have been significant in influencing the performance of the bearings. Sets of MOM bearings with different clearances were investigated in this study using a hip friction simulator to examine the influence of clearance on friction, lubrication and squeaking. The friction factor was found to be highest in the largest clearance bearings under all test conditions. The incidence of squeaking was also highest in the large clearance bearings, with all bearings in this group squeaking throughout the study. A very low incidence of squeaking was observed in the other two clearance groups. The measured lubricating film was found to be lowest in the large clearance bearings. This study suggests that increasing the bearing clearance results in reduced lubricant film thickness, increased friction and an increased incidence of squeaking.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Bearing Couple, Lubricant and Swing Phase Load Conditions on the Friction of 28mm Hip Replacements

INTRODUCTION The majority of current artificial hip implants use a material combination of ultra-high molecular-weight polyethylene against metal or ceramic. However, it is well documented that the wear debris from these prostheses contributes to osteolysis and ultimate failure of the prosthesis, hence alternative materials have been sought, such as metalon-metal and ceramic-on-ceramic [1]. Mor...

متن کامل

Transient elastohydrodynamic lubrication analysis of a novel metal-on-metal hip prosthesis with a non-spherical femoral bearing surface.

Effective lubrication performance of metal-on-metal hip implants only requires optimum conformity within the main loaded area, while it is advantageous to increase the clearance in the equatorial region. Such a varying clearance can be achieved by using non-spherical bearing surfaces for either acetabular or femoral components. An elastohydrodynamic lubrication model of a novel metal-on-metal h...

متن کامل

Friction of total hip replacements with different bearings and loading conditions.

Metal-on-ultra-high molecular weight polyethylene (UHMWPE) total hip replacements have been the most popular and clinically successful implants to date. However, it is well documented that the wear debris from these prostheses contributes to osteolysis and ultimate failure of the prosthesis, hence alternative materials have been sought. A range of 28 mm diameter bearings were investigated using...

متن کامل

Predictive wear modeling of the articulating metal-on-metal hip replacements.

The lubrication regime in which artificial hip joints operate adds complexity to the prediction of wear, as the joint operates in both the full fluid film regime-specifically the elastohydrodynamic lubrication (EHL) regime-and the mixed or boundary lubrication regimes, where contact between the bearing surfaces results in wear. In this work, a wear model is developed which considers lubrication...

متن کامل

Experimental Investigation of Metal Powder Compaction without Using Lubricant

The main objective of this work was to design a novel device for compaction of metal powders so that the green parts could be ejected with applying a negligible force and without the need for any lubricant in either an admixed form or applied to the die wall. For this purpose a 40 mm diameter one-piece die was envisaged which would elastically contracted 0.076 mm before compaction and after com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of materials science. Materials in medicine

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 2008