Assessing the Performance of Cooling Towers and Their Effect on Chiller Efficiency

نویسندگان

  • Donald Kasten
  • Michael R. Muller
چکیده

Traditionally, energy recommendations from energy audits have been concerned with the energy use of cooling towers for point of use energy, such as variable speed fans, and pumping savings. The actual energy use of a cooling tower is small, and is only a portion of the energy involved in the entire cooling system. The majority of the energy used is to perform the work necessary to compress the refrigerant at the chiller, and is most commonly defined by the term coefficient of performance. The efficiency of a tower is based on the original design conditions as well as the type of tower (evaporative, draft driven). Inefficiencies can occur due to under or over sizing, controls that are not properly functioning, flawed strategies for operation, and basic lack of maintenance that can create fouling of the exchangers. This paper explores the efficiency relationship between the tower and the chiller, but more specifically develops a methodology to measure and estimate this efficiency on a short one or two day assessment. Modern inexpensive devices allow for measurement and monitoring of air temperature, humidity, process cooling temperatures and sump temperature to be measured on a short term basis. More importantly, these devices can be installed quickly by plant personnel and can be left in place for a week or more and possibly even mailed back to the auditor with the collected data. This paper includes information about how to determine the appropriate design conditions for the tower, its temporal performance, as well as tips from major tower manufactures on design, performance, and maintenance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Short-Term Scheduling of Multi-Chiller Plants Considering Energy Requirement of Cooling Towers, Pumps and Chillers

During extremely hot summer days, air conditioning systems are known as major electricity consumers in residential, commercial and industrial sectors. Moreover, high energy requirement of multiple-chiller plants may cause an interconnected power grid be faced with annual on-peak electrical demand, load-generation mismatch, voltage collapse and catastrophic wide area blackout. Therefore, this pa...

متن کامل

Effect of Ambient Condition on the Shower Cooling Tower in Four Type of Climates Condition

Water cooling by ambient takes place with two mechanisms of heat and mass transfer. Using packings at wet cooling towers has disadvantages such as obstruction, reduction of life expectancy and production of algae and fungi. In shower cooling towers types of towers packings are completely removed and water intake is in direct contact and heat transfer takes place in two ways of latent and sensib...

متن کامل

Thermoeconomic analysis of a hybrid PVT solar system integrated with double effect absorption chiller for cooling/hydrogen production

A novel solar-based combined system which is consisting of a concentrated PV, a double effect LiBr-H2O absorption chiller, and a Proton Exchange Membrane (PEM) is proposed for hydrogen production. A portion of the received energy is recovered to run a double effect absorption chiller and the rest is turned into electricity, being consumed in the PEM electrolyzer for hydrogen producti...

متن کامل

Thermodynamic diagnosis of a novel solar-biomass based multi-generation system including potable water and hydrogen production

In this study, a new proposed multi-generation system as a promising integrated energy conversion system is studied, and its performance is investigated thermodynamically. The system equipped with parabolic trough collectors and biomass combustor to generate electricity, heating and cooling loads, hydrogen and potable water. A double effect absorption chiller to provide cooling demand, a proton...

متن کامل

Study of Degradation of Dry Cooling Tower Performance under Wind Conditions and Method for Tower Efficiency Enhancement (RESEARCH NOTE)

Wind affects adversely the cooling tower thermal performance. A field investigation was carried out to study the thermal performance of Heller cooling towers under wind conditions, involving measurement of wind velocity and its direction around the cooling tower, and obtaining water flow rates and temperatures at the cooling tower inlet and outlet. Results show that air suction at the tower top...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007