Clinical results of mean GTV dose optimized robotic guided SBRT for liver metastases

نویسندگان

  • Nicolaus Andratschke
  • Alan Parys
  • Susanne Stadtfeld
  • Stefan Wurster
  • Stefan Huttenlocher
  • Detlef Imhoff
  • Müjdat Yildirim
  • Dirk Rades
  • Claus Michael Rödel
  • Jürgen Dunst
  • Guido Hildebrandt
  • Oliver Blanck
چکیده

BACKGROUND We retrospectively evaluated the efficacy and toxicity of gross tumor volume (GTV) mean-dose-optimized and real-time motion-compensated robotic stereotactic body radiation therapy (SBRT) in the treatment of liver metastases. METHODS Between March 2011 and July 2015, 52 patients were treated with SBRT for a total of 91 liver metastases (one to four metastases per patient) with a median GTV volume of 12 cc (min 1 cc, max 372 cc). The optimization of mean GTV dose was prioritized during treatment planning at the potential cost of planning target volume (PTV) coverage reduction while adhering to safe normal tissue constraints. The delivered median GTV biological effective dose (BED10) was 142.1 Gy10 (range, 60.2 Gy10 -165.3 Gy10) and the prescribed PTV BED10 ranged from 40.6 Gy10 to 112.5 Gy10 (median, 86.1 Gy10). We analyzed local control (LC), progression-free interval (PFI), overall survival (OS), and toxicity. RESULTS Median follow-up was 17 months (range, 2-49 months). The 2-year actuarial LC, PFI, and OS rates were 82.1, 17.7, and 45.0 %, and the median PFI and OS were 9 and 23 months, respectively. In univariate analysis histology (p < 0.001), PTV prescription BED10 (HR 0.95, CI 0.91-0.98, p = 0.002) and GTV mean BED10 (HR 0.975, CI 0.954-0.996, p = 0.011) were predictive for LC. Multivariate analysis showed that only extrahepatic disease status at time of treatment was a significant factor (p = 0.033 and p = 0.009, respectively) for PFI and OS. Acute nausea or fatigue grade 1 was observed in 24.1 % of the patients and only 1 patient (1.9 %) had a side effect of grade ≥ 2. CONCLUSIONS Robotic real-time motion-compensated SBRT is a safe and effective treatment for one to four liver metastases. Reducing the PTV prescription dose and keeping a high mean GTV dose allowed the reduction of toxicity while maintaining a high local control probability for the treated lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical introduction of Monte Carlo treatment planning for lung stereotactic body radiotherapy

The purpose of this study was to investigate the impact of Monte Carlo (MC) calculations and optimized dose definitions in stereotactic body radiotherapy (SBRT) for lung cancer patients. We used a retrospective patient review and basic virtual phantom to determine dose prescriptions. Fifty-three patients underwent SBRT. A basic virtual phantom had a gross tumor volume (GTV) of 10.0 mm with equi...

متن کامل

Stereotactic radiation therapy for liver metastases: factors affecting local control and survival

PURPOSE To report on outcome and toxicity of stereotactic body radiotherapy (SBRT) for liver metastases in patients not eligible for surgery. METHODS From 2000 to 2009, 74 patients with 91 liver metastases from different primaries have been treated with SBRT at our institution. Median planning target volume was 123 ccm (range: 10.6-1074 ccm). Treatment consisted of 3-5 fractions with 5-12.5 G...

متن کامل

Prognostic factors affecting local control of hepatic tumors treated by stereotactic body radiation therapy

PURPOSE Robotic Stereotactic Body Radiation Therapy with real-time tumor tracking has shown encouraging results for hepatic tumors with good efficacy and low toxicity. We studied the factors associated with local control of primary or secondary hepatic lesions post-SBRT. METHODS AND MATERIALS Since 2007, 153 stereotactic liver treatments were administered to 120 patients using the CyberKnife®...

متن کامل

Evaluation of dosimetric misrepresentations from 3D conventional planning of liver SBRT using 4D deformable dose integration

The purpose of this study is to evaluate dosimetric errors in 3D conventional plan- ning of stereotactic body radiotherapy (SBRT) by using a 4D deformable image registration (DIR)-based dose-warping and integration technique. Respiratory- correlated 4D CT image sets with 10 phases were acquired for four consecutive patients with five liver tumors. Average intensity projection (AIP) images were ...

متن کامل

Analysis of the factors affecting the safety of robotic stereotactic body radiation therapy for hepatocellular carcinoma patients

Objective The objective of this study was to investigate the safety of robotic stereotactic body radiation therapy (SBRT) for hepatocellular carcinoma (HCC) patients and its related factors. Methods A total of 74 HCC patients with Child-Turcotte-Pugh (CTP) Class A were included in a multi-institutional, single-arm Phase II trial (NCT 02363218) between February 2013 and August 2016. All patien...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016