Commutability of two JCTLM-listed secondary reference materials for two commercial lithium assays.
نویسندگان
چکیده
Fig. 1. Regression analysis (regression line – continuous – and 95% prediction interval – dashed lines) to evaluate commutability of IRMM BCR-304 (triangle) and NIST SRM 956c (black circles) between direct potentiometry and colorimetry assays for serum lithium. Gray circles identify native serum samples. Commutability of two JCTLM-listed secondary reference materials for two commercial lithium assays
منابع مشابه
Commutability of the ERM-DA470k reference material for two assays measuring serum albumin using immunochemical principles.
The standardization of measurements is a high-priority in Laboratory Medicine; its purpose being to achieve closer comparability of results for the same analyte obtained using different commercial systems (1). The promotion of result traceability to available higher-order reference measurement procedures and reference materials is the recommended approach (2). A major prerequisite for guarantee...
متن کاملStandardisation of cardiac troponin I measurement: past and present.
The laboratory measurement of cardiac troponin (cTn) concentration is a critical tool in the diagnosis of acute myocardial infarction (MI). Current cTnI assays produce different absolute troponin numbers and use different clinical cut-off values; hence cTnI values cannot be interchanged, with consequent confusion for clinicians. A recent Australian study compared patient results for seven cTnI ...
متن کاملToward standardization of cardiac troponin I measurements part II: assessing commutability of candidate reference materials and harmonization of cardiac troponin I assays.
BACKGROUND Cardiac tropoin I (cTnI) measurements show an approximately 20- to 40-fold difference between assays, and better standardization and harmonization are needed. Toward this goal, the AACC cTnI Standardization Committee collaborated with the National Institute of Standards and Technology (NIST) in an earlier study to select 2 candidate reference materials (cRMs). METHODS Two troponin ...
متن کاملCommutability of Possible External Quality Assessment Materials for Cardiac Troponin Measurement
BACKGROUND The measurement of cardiac troponin is crucial in the diagnosis of myocardial infarction. The performance of troponin measurement is most conveniently monitored by external quality assessment (EQA) programs. The commutability of EQA samples is often unknown and the effectiveness of EQA programs is limited. METHODS Commutability of possible EQA materials was evaluated. Commercial co...
متن کاملToward standardization of carbohydrate-deficient transferrin (CDT) measurements: III. Performance of native serum and serum spiked with disialotransferrin proves that harmonization of CDT assays is possible.
Carbohydrate-deficient transferrin (CDT) is a generic term that refers to the transferrin glycoforms whose concentration in blood is temporarily increased by sustained alcohol consumption. Due to high clinical specificity, CDT was proposed as a biomarker of heavy alcohol use and has been available for about 20 years. A number of methods have been developed for CDT measurement based on different...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinica chimica acta; international journal of clinical chemistry
دوره 414 شماره
صفحات -
تاریخ انتشار 2012