Evaluation of personal dose equivalent using optically stimulated luminescent dosemeters in Marumori after the Fukushima nuclear accident.
نویسندگان
چکیده
The personal dose equivalent for 36 Marumori residents living in wooden houses was evaluated using optically stimulated luminescent dosemeters after the Fukushima nuclear accident. The cumulative doses to residents over 200 d from 1 September 2011 ranged from 536 to 1490 µSv. In each resident's house, the indoor and outdoor ambient dose equivalents were measured with an NaI scintillation survey meter. A linear relationship with a slope of 0.5 was found between them; however, the ratio of the indoor to the outdoor ambient dose equivalent varied from 0.36 to 1.0. A better linear relationship was observed between the personal dose equivalent and the indoor ambient dose equivalent compared with that between the personal dose equivalent and the outdoor ambient dose equivalent. These results indicate that the individual exposure dose depends on the indoor ambient dose equivalent rather than the outdoor ambient dose equivalent. These results should be very helpful in obtaining the countermeasures to reduce residents' exposure dose.
منابع مشابه
Importance of personal dose equivalent evaluation in Fukushima in overcoming social panic.
The relationship between the reported ambient dose equivalent (H*(10)) and the individual dose rate recorded by medical staff in Fukushima City after the accident at the Fukushima Daiichi nuclear power plant was evaluated, following a 9.0-magnitude earthquake that struck the east coast of Japan. Personal dose equivalent (H(p)(10)) ranged from 0.08 to 1.63 µSv h(-1) and H*(10) ranged from 0.86 t...
متن کاملEvaluation of individual dosimetry in mixed neutron and photon radiation fields (EVIDOS). Part I: Scope and methods of the project.
Supported by the European Commission, the EVIDOS project started in November 2001 with the broad goal of evaluating state of the art dosimetry techniques in representative workplaces of the nuclear industry. Seven European institutes joined efforts with end users at nuclear power plants, at fuel processing and reprocessing plants, and at transport and storage facilities. A comprehensive program...
متن کاملMeasurements and Calculations of Beta Dose Rates on Contaminated Ground at the Fukushima Daiichi Nuclear Power Plant Site
The accident at the Fukushima Daiichi Nuclear Power Plant resulted in a substantial release of radionuclides into the environment. Consequently, the emergency operation workers were exposed to both external gamma and beta radiations arising from the fallout; however, their beta doses were scarcely recorded at the time due to an insufficient number of dosemeters. To solve this problem, the autho...
متن کاملCalculation of airkerma conversion factor to personal dose equivalent at various depths using the Monte Carlo Code GATE
Several studies have been done with the aim of improving the quality of the radiation protection measurement in radiology and nuclear medicine. Among different subjects which are capable to be considered in this area, the measurement of the operational quantities of protection against the radiation ,such as, personal dose equivalent ,HP(d), at different depths (d=0.07mm, 3mm, 10mm) is an impor...
متن کاملTest of household salt read by optically stimulated luminescence (OSL) as a personal dosemeter
This study has investigated the optically stimulated luminescence (OSL) of household salt and chemically pure NaCl after exposure in different radiation environments. The response relative to thermoluminescent dosimetry using LiF has been investigated to determine if OSL in NaCl can be considered as an alternative to measurements of thermoluminescence in LiF. A selection of staff members at the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 154 3 شماره
صفحات -
تاریخ انتشار 2013