In vitro compound A formation in a computer-controlled closed-circuit anesthetic apparatus. Comparison with a classical valve circuit.

نویسندگان

  • L F Versichelen
  • G Rolly
  • M P Bouche
  • J F Van Bocxlaer
  • M M Struys
  • C Van Der Herten
  • A P De Leenheer
  • E P Mortier
چکیده

BACKGROUND Few data exist on compound A during sevoflurane anesthesia when using closed-circuit conditions and sodalime with modern computer-controlled liquid injection. METHODS A PhysioFlex apparatus (Dräger, Lübeck, Germany) was connected to an artificial test lung (inflow approximately 160 ml/min carbon dioxide, outflow approximately 200 ml/min, simulating oxygen consumption). Ventilation was set to obtain an end-tidal carbon dioxide partial pressure (Petco2) approximately 40 mmHg. Canister inflow (T degrees in) and outflow (T degrees out) temperatures were measured. Fresh sodalime and charcoal were used. After baseline analysis, sevoflurane concentration was set at 2.1% end-tidal for 120 min. At baseline and at regular intervals thereafter, Petco2, end-tidal sevoflurane, T degrees in, and T degrees out were measured. For inspiratory and expiratory compound A determination, samples of 2-ml gas were taken. These data were compared with those of a classical valve-containing closed-circuit machine. Ten runs were performed in each set-up. RESULTS Inspired compound A concentrations increased from undetectable to peak at 6.0 (SD 1.3) and 14.3 (SD 2.5) ppm (P < 0.05), and maximal temperature in the upper outflow part of the absorbent canister was 24.3 degrees C (SD 3.6) and 39.8 degrees C (SD 1.2) (P < 0.05) in the PhysioFlex and valve circuit machines, respectively. Differences between the two machines in compound A concentrations and absorbent canister temperature at the inflow and outflow regions were significantly different (P < 0.05) at all times after 5 min. CONCLUSION Compound A concentrations in the high-flow (70 l/min), closed-circuit PhysioFlex machine were significantly lower than in conventional, valve-based machines during closed-circuit conditions. Lower absorbent temperatures, resulting from the high flow, appear to account for the lower compound A formation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Comparison of a Sensorless Driver Circuit for Switched Reluctance Motor

In the presented paper, a sensorless driver circuit is designed, constructed and tested to control two types of three-phase Switched Reluctance Motor (SRM). The presented control algorithm has three steps. In the first step, the SRM is controlled by an open-loop method. In the second step, mathematical model of the SRM phase, motor parameters and flux-current-rotor position relation are used in...

متن کامل

A Comparison Between Electrical Circuit and Finite Element Modeling Methods for Performance Analysis of a Three-Phase Induction Motor under Voltage Unbalance

Induction motor is the most popular load in the industry, it is very important to study about the effects of voltage quality on induction motor performance. One of the most important voltage quality problems in power system is voltage unbalance. This paper evaluates and compares two methods including finite element method (FEM) and equivalent electrical circuit simulation for investigation ...

متن کامل

A Novel Design of Reversible Multiplier Circuit (TECHNICAL NOTE)

Adders and multipliers are two main units of the computer arithmetic processors and play an important role in reversible computations. The binary multiplier consists of two main parts, the partial products generation circuit (PPGC) and the reversible parallel adders (RPA). This paper introduces a novel reversible 4×4 multiplier circuit that is based on an advanced PPGC with Peres gates only. Ag...

متن کامل

Control of Series Resonant Converter with Robust Performance Against Load and Power Circuit Components Uncertainties

Robust performance controller design for duty-cycle controlled series resonant converter (SRC) is proposed in this paper. The uncertainties of the converter are analyzed with load variation and power circuit components tolerances are taken into consideration. Additionally, a nominal performance (NP) controller is designed. Closed-loop system is simulated with Orcad and simulation results of r...

متن کامل

A New Approach to Flow Network Analysis of an Engine Lubrication System

In order to develop more efficient engines, it is essential to optimize the lubrication circuit of the power train systems. In this paper, during an engine design and development process, a network analysis of the engine lubrication system is described in detail. Two elements have been added to the lubrication circuit in the modified engine. These elements are hydraulic lifters and an Anti-d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 93 4  شماره 

صفحات  -

تاریخ انتشار 2000