Histological comparison of corneal ablation with Er:YAG laser, Nd:YAG optical parametric oscillator, and excimer laser.

نویسندگان

  • W B Telfair
  • C Bekker
  • H J Hoffman
  • P R Yoder
  • R E Nordquist
  • R A Eiferman
  • H H Zenzie
چکیده

PURPOSE To use histological techniques to assess and compare the ablation depth, local damage, and surface quality of corneal ablations by a Q-switched Er:YAG laser, an optical parametric oscillator laser at 2.94 microm, a long pulse Er:YAG laser, and a 193-nm excimer laser. METHODS Human cadaver eyes and in vivo cat eyes were treated with a 6.0-mm diameter, 30-microm-deep phototherapeutic keratectomy ablation and a 6.0-mm diameter, -5.00-D photorefractive keratectomy ablation. Human cadaver eyes were also treated with a 5.0-mm diameter, -5.00-D laser in situ keratomileusis (LASIK) ablation. Fluences and pulse widths used were 200 mJ/cm2 and 70 ns for the Q-switched Er:YAG, 150 mJ/cm2 and 7 ns for the optical parametric oscillator laser (OPO), 500 mJ/cm2 and 50 microseconds for the long pulse Er:YAG, and 160 mj/cm2 and 20 ns for the excimer laser. In the ablation rate study, 12 porcine eyes were ablated by the OPO laser with a range of layers and at different fluences ranging from 60 to 150 mJ/cm2, all using a 1.5-mm spot on the eye. The ablation depth of these acute ablations was evaluated by light microscopy examination. RESULTS In the acute damage study, light microscopy showed a thin surface layer in all samples with minimal thermal damage except on the long pulse Er:YAG corneas. Transmission electron microscopy revealed less than 0.3-microm surface damage for all specimens of both the optical parametric oscillator and the excimer laser samples with no evidence of collagen shrinkage. Transmission electron microscopy showed damage layers of 0.5 to 3 microm for Q-switched Er:YAG and 3 to 10 microm for long pulse Er:YAG. Scanning electron microscopy showed smooth surfaces in all eyes, although the excimer was the roughest. In the porcine eye study, ablations were produced in both PTK and PRK modes with the ablation rate per layer increasing with the fluence. At 120 mJ/cm2, the average ablation rate was 1.9 microm per layer. CONCLUSIONS The histology from the short pulse mid-infrared optical parametric oscillator laser at 2.94 microm was comparable to the 193-nm excimer with a smooth, damage-free, ablation zone when performing PRK and LASIK.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser Ablation Inductively Coupled Plasma

Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is one of the most successful direct solid sampling techniques for major, minor and trace element analysis. However, this technique still suffers from matrix dependent ablation characteristics, which makes quantification very difficult. Furthermore, the laser sampled material alters its composition from the sample to the de...

متن کامل

Healing after photorefractive keratectomy in cat eyes with a scanning mid-infrared Nd:YAG pumped optical parametric oscillator laser.

PURPOSE To evaluate the healing characteristics of cat corneas treated with a new scanning mid-infrared laser system. METHODS Six adult cats were treated with 6-mm diameter photorefractive keratectomy (PRK) corrections. One eye in each animal was untreated as a control and the other was treated with either a -3.00 or -6.00 diopter ablation. The laser was a new Nd:YAG pumped optical parametric...

متن کامل

"Orientation teeth" in non-mechanical laser corneal trephination for penetrating keratoplasty: 2.94 microm Er:YAG v 193 nm ArF excimer laser.

BACKGROUND/AIMS "Orientation teeth" at the donor trephination margin and correspondent "notches" at the host margin facilitate graft orientation and avoid "horizontal torsion" induced by asymmetric suture placement. In this study the quality and reproducibility of these structures created by non-mechanical laser corneal trephination were compared using two laser emissions. METHODS The procedu...

متن کامل

“Orientation teeth” in non-mechanical laser corneal trephination for penetrating keratoplasty: 2.94 μm Er:YAG v 193 nm ArF excimer laser

Background/aims—“Orientation teeth” at the donor trephination margin and correspondent “notches” at the host margin facilitate graft orientation and avoid “horizontal torsion” induced by asymmetric suture placement. In this study the quality and reproducibility of these structures created by non-mechanical laser corneal trephination were compared using two laser emissions. Methods—The procedure...

متن کامل

Gas chromatographic and mass spectroscopic analysis of excimer and erbium: yttrium aluminum garnet laser-ablated human cornea.

The photoablative products from human cadaver corneas treated with lasers were investigated using gas chromatography and mass spectroscopy. The photoablations were done separately with an excimer laser (193 nm) and with an erbium: yttrium aluminum garnet (Er:YAG) laser (2.94 microns). More than 20 different types of molecules with a molecular weight of 40-400 mass units could be identified, mos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2000