Cardiac perforation from implantable cardioverter-defibrillator lead placement: insights from the national cardiovascular data registry.
نویسندگان
چکیده
BACKGROUND Cardiac perforation is a feared complication of implantable cardioverter-defibrillator (ICD) lead implantation because of the potential for significant morbidity and mortality. Predictors of perforation and the severity of associated adverse events have not been well studied. We sought to identify predictors of cardiac perforation from ICD lead implantation and subsequent outcomes. METHODS AND RESULTS We studied 440 251 first-time ICD recipients in the ICD Registry implanted between January 2006 and September 2011. Using hierarchical multivariable logistic regression adjusting for patient, implanting physician, and hospital characteristics, we examined the predictors of perforation and the association of perforation with other major complications, length of stay, and in-hospital mortality. Cardiac perforation occurred in 625 patients (0.14%). After multivariable adjustment, older age, female sex, left bundle branch block, worsened heart failure class, higher left ventricular ejection fraction, and non-single-chamber ICD implant were associated with a greater odds of perforation. Conversely, atrial fibrillation, diabetes mellitus, previous cardiac bypass surgery, and higher implanter procedural volume were associated with a lower odds of perforation (all P<0.05). After adjustment, ICD recipients with perforation had greater odds of other associated major complications (odds ratio, 27.5; 95% confidence interval, 19.9-38.0; P<0.0001), postprocedural hospital stays >3 days (odds ratio, 16.3; 95% confidence interval, 13.7-19.4; P<0.0001), and in-hospital death (odds ratio, 17.7; 95% confidence interval, 12.2-25.6; P<0.0001). CONCLUSIONS In a large population of ICD recipients, specific patient and implanter characteristics predicted cardiac perforation risk. Cardiac perforation was associated with a substantially increased risk of other major complications, prolonged hospital stays, and death.
منابع مشابه
THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملIs correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
متن کاملزندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیدهشناسی
Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...
متن کاملImplantable Cardioverter‐Defibrillators for Secondary Prevention of Sudden Cardiac Death: A Review
F irst used in humans in 1980, the implantable cardioverter defibrillator (ICD) was designed to recognize and treat malignant ventricular arrhythmias and thus prevent arrhythmic death. Among patients with an aborted episode of sudden cardiac arrest (SCA) due to ventricular arrhythmias without a reversible cause, the ICD is considered an important therapy for secondary prevention of SCA and is s...
متن کاملFrom the National Cardiovascular Data Registry and Mortality Among Implantable Cardioverter-Defibrillator Recipients: Insights Low Body Mass Index but Not Obesity Is Associated With In-Hospital Adverse Events
Jonathan C. Hsu, Paul D. Varosy, Haikun Bao, Yongfei Wang, Jeptha P. Curtis and From the National Cardiovascular Data Registry and Mortality Among Implantable Cardioverter-Defibrillator Recipients: Insights Low Body Mass Index but Not Obesity Is Associated With In-Hospital Adverse Events Online ISSN: 2047-9980 Greenville Avenue, Dallas, TX 72514 JAHA: Journal of the American Heart Association i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular quality and outcomes
دوره 6 5 شماره
صفحات -
تاریخ انتشار 2013