P waves during ectopic atrial rhythms in man: a study utilizing atrial pacing with fixed electrodes.
نویسندگان
چکیده
Threshold bipolar pacing was performed from one of 12 selected atrial sites with temporary implanted electrodes in 69 patients following open-heart surgery in order to study P wave polarity and morphology and the P-R interval during paced ectopic atrial rhythms. A negative P wave was recorded in lead I only with pacing the left atrium and only when pacing near the left pulmonary veins. A positive bifid P wave in V1 was recorded only with left atrial pacing and only when pacing was near the inferior pulmonary veins and coronary sinus. P wave polarity and morphology were otherwise of no use in localization of the origin of the impulse in these studies. The pacing stimulus to P wave interval was found to vary between 10 and 54 msec, making the duration of the P-R interval an unreliable indicator of the site of origin of the paced impulse. Although the relation of these paced rhythms to spontaneously occurring ectopic rhythms is unclear, the previously published criteria for localizing ectopic atrial rhythms are again demonstrated to be unreliable. P wave polarity and morphology and the P-R interval are of limited value in ascertaining the origin of ectopic atrial rhythms in man.
منابع مشابه
Studies on left atrial automaticity in dogs.
The site of origin and the sequence of atrial activation were studied in 21 open-chested dogs anesthetized with sodium pentobarbital. Bipolar plunge electrodes were used to record atrial electrograms simultaneously with surface lead II and His bundle electrogram. In sinus rhythm the sinus node was activated first, followed sequentially by Bachmann's bundle, right atrial appendix, left atrial ap...
متن کاملAtrial Tachycardia Originating from the Cavo-Tricuspid Isthmus May Exhibit Narrow P Waves
An 83-year-old man underwent electrophysiological testing for focal atrial tachycardia (AT) exhibiting narrow P waves with negative deflections in the inferior leads. Catheter ablation at the cavo-tricuspid isthmus (CTI) successfully eliminated the AT. The propagation map during AT and pacing study from the successful ablation site demonstrated that the atrial activation throughout the CTI did ...
متن کاملAtrial excitability and conduction during rapid atrial pacing.
Using temporary atrial wire electrodes placed at selected atrial sites, rapid atrial pacing at rates of up to 368 beats/min was used to study atrial excitability and conduction in seven patients who underwent open heart surgery. The threshold for atrial pacing was found to be an exponential function of pacing rate (r = 0.55, p less than 0.01), increasing threefold when the fastest pacing rates ...
متن کاملSinoatrial pacemaker shift following atrial stimulation in man.
Indirect evidence of a sinoatrial pacemaker shift after programmed atrial stimulation in man is presented. Following electrically induced beats, time intervals and postextrasystolic morphology of atrial electrogram and P waves were scrutinized in 30 catheterization studies. Applying premature atrial stimulation, a decrease of the interval between the last basic atrial depolarization and the sti...
متن کاملEffects Of Fast Pathway Ablation On The Concealment Zone And Electrophysiological Behavior Of AV-Node During Atrial Fibrillation.
Objectives: Dual pathways have a determinant role in the occurrence of atrio nodal tachyarrhythmia (AVNRT). The aim of present study is to determine the role of slow pathway (SP) in the concealment zone and protective role of AV node during atrial fibrillation (AF). Material &Methods: In 7 isolated nodal rabbit preparation zone of concealment and concealed conduction is quantified by Specif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 52 3 شماره
صفحات -
تاریخ انتشار 1975