Flow Cytometric Assessment of Erythrocyte Shape through Analysis of FSC Histograms: Use of Kurtosis and Implications for Longitudinal Evaluation

نویسندگان

  • Christoph Ahlgrim
  • Torben Pottgiesser
  • Thomas Sander
  • Yorck Olaf Schumacher
  • Manfred W. Baumstark
چکیده

Sphericity of erythrocytes can be estimated from analysis of FSC signal distribution in flow cytometry. Previously, Pearson's coefficient of dissymmetry (PCD) and spherical index (SphI) were applied to determine erythrocyte sphericity from the FSC histogram. The aim of the present study is to illustrate the application of kurtosis as an indicator of erythrocyte sphericity in flow cytometry in a broad range of FSC distributions. Moreover, the possibility of longitudinal evaluation of erythrocyte sphericity is studied. Change of erythrocyte sphericity of 10 healthy subjects was induced by variation of buffer osmolarity to validate applicability of sphericity measures. Agreement between the sphericity indicators was then studied in samples from 20 healthy donors taken at three time points, which were processed through density gradient centrifugation and incubated with FITC-labelled antibodies to induce a broad variation of erythrocyte form (1086 samples). SphI, PCD and kurtosis of FSC distribution were calculated. Correlation of the respective measures, standard error of measurement (SEM) and r ratio (intra- to interindividual variance) were determined to illustrate agreement between the sphericity indicators. In the first study part, all sphericity indicators illustrated change of erythrocyte shape as induced by osmolarity variation. In the second part, correlation between kurtosis and SphI was -0.97 and correlation between kurtosis and PCD was 0.58 (p<0.05). In isotype control samples, correlation between kurtosis and SphI was -0.98 and correlation between kurtosis and PCD was 0.48 (p<0.05). In these samples, mean kurtosis was -0.80 (SEM 0.03), mean SphI was 2.19 (SEM 0.04) and mean PCD was -0.31 (SEM 0.02). r ratios of all measures of sphericity were <0.6. Our results show that kurtosis is closely correlated with SphI in a broad range of erythrocyte FSC distributions. Moreover, all measures of sphericity feature r ratios <0.6, highlighting that erythrocyte sphericity appears as a feasible parameter for individual longitudinal data monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of Four-Color Flow Cytometric Assay for Discrimination of Hematogone from Lymphoblast: Critical Issue for MRD Assessment in B-ALL Patients

Background: Hematogones are normal B-cell precursor which can be seen in different physiological and pathological conditions. Due to variation in B-cell acute lymphoblastic leukemia (B-ALL) blasts immunophenotyping and interference of hematogones in minimal residual disease (MRD) assessment, precise discrimination of hematogones is very crucial.  The purpose of this study was to evaluate the ex...

متن کامل

Flow Cytometric DNA Analysis and Histopathologic Re-Evaluation of Paraffin Embedded Samples from Hydatidiform Moles and Hydropic Abortions

Background Distinction of hydatidiform moles (HMs) from non-molar abortions and sub-classification of HMs are important for clinical practice; yet, diagnosis based solely on morphology is affected by interobserver variability. The objective of this study was to determine the role of DNA flow cytometry in distinguishing molar from non-molar pregnancies. MaterialsAndMethods This retrospective stu...

متن کامل

تفسیر هیستوگرام‏های اریتروسیتی به‌دست‌آمده از دستگاه‏های خودکار هماتولوژی در بیماری‏های خونی معمول

Background: Presently, the graphical data of blood cells (histograms and cytograms or/ scattergrams) that they are usually available in all modern automated hematology analyzers are an integral a part of automated complete blood count (CBC). To find incorrect results from automated hematology analyzer and establish the samples that require additional analysis, Laboratory employees will use thos...

متن کامل

Assessment of Equine Autoimmune Thrombocytopenia (EAT) by flow cytometry

RATIONALE: Thrombocytopenia is a platelet associated process that occurs in human and animals as result of i) decreased production; ii) increased utilization; iii) increased destruction coupled to the presence of antibodies, within a process know as immune-mediated thrombocytopenia (IMT); or iv) platelet sequestration. Thus, the differentiation of the origin of IMT and the development of reliab...

متن کامل

A Numerical Analysis for the Effect of Slip Velocity and Stenosis Shape on Non-Newtonian Flow of Blood (TECHNICAL NOTE)

The aim of this paper is to study the effect of slip velocity and shape of stenosis on non-Newtonian flow of blood through a stenosed arterial segment. Blood is modeled as Bingham-Plastic fluid in a uniform circular tube with a radially non-symmetric stenosis. The problem is investigated by a joint effort of analytical and numerical techniques. The influence of stenosis shape parameter, slip ve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013