Recruitment and blocking properties of the CardioFit stimulation lead.

نویسندگان

  • Tamar Ahilea Anholt
  • Shai Ayal
  • Joshua A Goldberg
چکیده

The CardioFit vagal stimulation system has been developed as a proposed therapy for congestive heart failure (CHF). CardioFit is to be implanted in several hundred CHF patients enrolled in the INOVATE-HF clinical trial, an FDA approved study. The CardioFit stimulation lead (CSL), which is a cuff electrode that delivers stimulation pulses to the right cervical vagus, was designed to recruit efferent cardiac vagal fibers while minimizing unwanted recruitment of other fibers. This paper presents the CSL and measurements of its recruiting and blocking properties when placed on isolated porcine vagus nerves maintained at an elevated temperature in oxygenated artificial cerebrospinal fluid. Using charge balanced quasi-trapezoidal pulses driven through the CSL, we show in eight out of nine nerves a 63% ± 13% (mean ± SD) unidirectional attenuation of the A-fiber compound action potential attained at a current of 3.0 ± 0.8 mA. The threshold for the activation of A- and B-fibers was found to be 0.3 ± 0.17 mA and 2.5 ± 1.1 mA, respectively. The results presented here should help to guide the optimal parameters used in the upcoming deployment of the CardioFit system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving Petrophysical Interpretation of Conventional Log ‎by Determination of Real Bed Boundaries

Proper determination of bed boundaries in layered reservoirs is vital ‎for accurate petrophysical interpretation of conventional logs. In the ‎wellbore, logs continuously measure physical properties of reservoir ‎while the properties change stepwise. This continuous representation ‎of logs may lead to ignorance of some high potential reservoir zones. ‎The main reasons for continuous nature of l...

متن کامل

Evaluation of H-reflex recruitment curve after application of TENS on the desensitised skin of vertebral column

Electrical stimulation of neuromuscular system has been used in a variety of research and therapeutic applications. Although tri-polar transcutaneous electrical stimulation (TENS) is commonly used to change motoneuron excitabi1ity, but the effect of TENS on synaptic activities through dorsal column stimulation or cutaneous pathways is unknown. So, the aim of this research study was to determine...

متن کامل

The effect of lead (Pb2+) on electrophysiological properties of calcium currents in F77 neuron in Helix aspersa

Ion channels are responsible for control of cell function in excitable tissues such as heart and brain and also in organs and tissues traditionally thought to be non- excitable including liver and epithelium. In the present research, the effect of lead (Pb2+) on Ca2+ -dependent action potential and currents was studied in F77 neuronal soma membrane of Helix aspersa. For this purpose, action pot...

متن کامل

The effects of vertebral column tripolar electrical stimulation with various intensities on soleus and gastrocnemius H-reflex and Mh wave recruitment curve

Abstract: To assess the effect of penetration depth of the surface tripolar electrical stimulation, Tripolar TENS was applied with different intensities (equal to sensory threshold (ST), 1.25 ST, 1.5 ST) on vertebral column of twenty healthy and three hemiplegic subjects. The cathode of TENS was laid on the T11 vertebra and anodes were put 3cm apart from cathode, longitudinally and in the anod...

متن کامل

Extraction of a CardioFix neurostimulator with concomitant laser-assisted lead and intracardiac cardiac defibrillator extraction due to Staphylococcus aureus pocket infection

Case report A 61-year-old man with a history of ischemic cardiomyopathy status post dual-chamber Medtronic Evera XT AICD implanted in the left infraclavicular fossa area in 2007 was subsequently enrolled in the Innervate HF trial in 2013 and had a CardioFix (BioControl Medical LTD, Yehud, Isreal) neurotransmitter implanted. The patient developed severe Staphylococcus aureus infection of his AIC...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neural engineering

دوره 8 3  شماره 

صفحات  -

تاریخ انتشار 2011