The SRK regression formula in calculating the dioptric power of intraocular lenses.
نویسندگان
چکیده
One hundred and seventy one eyes with intraocular lenses were studied to compare the predictive accuracy of the Fyodorov and Van der Heijde theoretical formulae of the Sanders-Retzlaff-Kraff (SRK) regression formula. The SRK regression formula was the most accurate. Our personal calculations of the A constants of this formula are given for several types of implants and manufacturers.
منابع مشابه
Comparison of intraocular lens power calculation using the Binkhorst and SRK formulae: a clinical study.
Comparison of results of intraocular lens implants with IOL powers obtained by Binkhorst and SRK Linear Regression formulae was done using various models and brands of intraocular lenses. Of 887 pseudophakic patients. 415 patients received IOL's with their powers calculated for planned emmetropia, by means of theoretic formula devised by R.D. Binkhorst and in the remaining 472 eyes the IOL powe...
متن کاملAccuracy of Intraocular Lens Power Formulas Involving 148 Eyes with Long Axial Lengths: A Retrospective Chart-Review Study
Purpose. This study aims to compare the accuracy of intraocular lens power calculation formulas in eyes with long axial lengths from Chinese patients subjected to cataract surgery. Methods. A total of 148 eyes with an axial length of >26 mm from 148 patients who underwent phacoemulsification with intraocular lens implantation were included. The Haigis, Hoffer Q, Holladay 1, and SRK/T formulas w...
متن کاملVisual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus
Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...
متن کاملIntraocular Lens Power Calculation after Corneal Refractive Surgery
PURPOSE To determine the accuracy of a method of calculating intraocular lens (IOL) power after corneal refractive surgery. SETTING Department of Ophthalmology, Hospital de Gipuzkoa, San Sebastián, Spain. METHODS The SRK/T formula was modified to use the pre refractive surgery K-value (Kpre) for the effective lens position (ELP) calculation and the post refractive surgery K-value (Kpost) fo...
متن کاملIntraocular lens power calculation for cataract surgery after photorefractive keratectomy.
OBJECTIVE To assess intraocular lens (IOL) power calculations in patients undergoing cataract surgery after excimer laser photorefractive keratectomy (PRK) for myopia. METHODS Four eyes of two patients underwent phacoemulsification with IOL implantation after PRK for myopia. The estimated refractive error that would have been induced had the IOL predicted for emmetropia been implanted was cal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 68 4 شماره
صفحات -
تاریخ انتشار 1984