Effect of mask dead space and occlusion of mask holes on delivery of nebulized albuterol.
نویسنده
چکیده
BACKGROUND Infants and children with respiratory conditions are often prescribed bronchodilators. Face masks are used to facilitate the administration of nebulized therapy in patients unable to use a mouthpiece. Masks incorporate holes into their design, and their occlusion during aerosol delivery has been a common practice. Masks are available in different sizes and different dead volumes. The aim of this study was to compare the effect of different degrees of occlusion of the mask holes and different mask dead space on the amount of nebulized albuterol available at the mouth opening in a model of a spontaneously breathing child. METHODS A breathing simulator mimicking infant (tidal volume [VT] = 50 mL, breathing frequency = 30 breaths/min, inspiratory-expiratory ratio [I:E] = 1:3), child (VT = 155 mL, breathing frequency = 25 breaths/min, I:E = 1:2), and adult (VT = 500 mL, breathing frequency = 15 breaths/min, I:E = 1:2) breathing patterns was connected to a collection filter hidden behind a face plate. A pediatric size mask and an adult size mask connected to a continuous output jet nebulizer were sealed to the face plate. Three nebulizers were loaded with albuterol sulfate (2.5 mg/3 mL) and operated with 6 L/min compressed air for 5 min. Experiments were repeated with different degrees of occlusion (0%, 50%, and 90%). Albuterol was extracted from the filter and measured with a spectrophotometer at 276 nm. RESULTS Occlusion of the holes in the large mask did not increase the amount of albuterol in any of the breathing patterns. The amount of albuterol captured at the mouth opening did not change when the small mask was switched to the large mask, except with the breathing pattern of a child, and when the holes in the mask were 50% occluded (P = .02). CONCLUSIONS Neither decreasing the dead space of the mask nor occluding the mask holes increased the amount of nebulized albuterol captured at the mouth opening.
منابع مشابه
Effect of face mask design on inhaled mass of nebulized albuterol, using a pediatric breathing model.
BACKGROUND Aerosol face mask design and the distance at which the face mask is held from the face affect the delivery of nebulized medication to pediatric patients. OBJECTIVE To measure the inhaled mass of nebulized albuterol with 3 types of pediatric face mask, at 3 different distances from the face, with a model of a spontaneously breathing infant. METHODS We compared a standard pediatric...
متن کاملEffect of nebulized ipratropium bromide on intraocular pressures in children.
STUDY OBJECTIVE To evaluate the effects of nebulized ipratropium bromide on intraocular pressures and pupillary responses in children with asthma. DESIGN A double-blind, randomized, crossover study. SETTING Children's Hospital of Winnipeg, University of Manitoba. PATIENTS OR PARTICIPANTS Age 6 to 17 years with asthma. INTERVENTION Nebulized ipratropium bromide added to albuterol sulfate...
متن کاملEffects of ventilator settings, nebulizer and exhalation port position on albuterol delivery during non-invasive ventilation: an in-vitro study
BACKGROUND Few studies have investigated the factors affecting aerosol delivery during non-invasive ventilation (NIV). Our aim was to investigate, using a bench-top model, the effect of different ventilator settings and positions of the exhalation port and nebulizer on the amount of albuterol delivered to a lung simulator. METHODS A lung model simulating spontaneous breathing was connected to...
متن کاملNebulized albuterol delivery in a model of spontaneously breathing children with tracheostomy.
BACKGROUND Nebulized therapy is commonly used in spontaneously breathing tracheostomized patients, despite a lack of recommended devices and techniques. I compared albuterol dose delivered to a model of spontaneously breathing children with tracheostomy, using different nebulizers, tracheostomy tube sizes, inhalation techniques, and breathing patterns. METHODS A tracheostomy model was connect...
متن کاملبررسی تاثیر اکسیژن تراپی با ماسک ونچوری و ماسک CPAP بر تهوع و استفراغ بعد از عمل جراحی سزارین
Aims and background: Nausea and vomiting is one of the most common and most annoying post-operative complications, therefore, the aim of this study was to investigate the effect of oxygen therapy with Venturi mask and CPAP mask on nausea and vomiting after cesarean section. Materials and methods: This quasi-experimental study was performed on two groups (control-intervention) on 90 candidates ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 59 8 شماره
صفحات -
تاریخ انتشار 2014