Application of the proximal flow convergence method to calculate the effective regurgitant orifice area in aortic regurgitation.

نویسندگان

  • C M Tribouilloy
  • M Enriquez-Sarano
  • S L Fett
  • K R Bailey
  • J B Seward
  • A J Tajik
چکیده

OBJECTIVES We sought to determine the reliability of the proximal isovelocity surface area (PISA) method for calculation of effective regurgitant orifice (ERO) of aortic regurgitation (AR). BACKGROUND The ERO area can be calculated by the PISA method, but this method has not been validated in AR. METHODS ERO calculation by the PISA method was undertaken prospectively in 71 consecutive patients with isolated AR and achieved in 64 and compared with two simultaneous reference methods (quantitative Doppler and quantitative two-dimensional echocardiography). In addition, this method was compared with angiography in 12 patients, with surgical assessment in 18 patients and with ventricular volumes in all patients. RESULTS Good correlations between PISA and reference methods were obtained (both r=0.90, both p < 0.0001), but a trend toward underestimation of the ERO by the PISA method was noted (24+/-19 vs. 26+/-22 mm2 and 27+/-23 mm2, respectively, both p=0.04). However, this trend was confined to five patients with an obtuse flow convergence angle (>220 degrees), and on multivariate analysis this variable was the only independent determinant of underestimation of the ERO. In contrast, in 59 patients with a flat flow convergence (< or =220 degrees ), the PISA method, in comparison with reference methods, showed excellent correlations, with a narrow standard error of the estimate (r=0.95, SEE 5.4 mm2, and r=0.95, SEE 5.8 mm2; all p < 0.0001) and no trend toward underestimation (22+/-18 vs. 23+/-16 mm2, p=0.44, and vs. 23+/-18 mm2, p=0.34). CONCLUSIONS In patients with AR, the PISA method can be used to measure the ERO with reasonable feasibility. Underestimation of the ERO by PISA may occur in patients with an obtuse flow convergence angle. However, in most patients with appropriate flow convergence, PISA provides reliable measurement of the ERO of AR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of color Doppler flow mapping to calculate effective regurgitant orifice area. An in vitro study and initial clinical observations.

BACKGROUND Analogous to stenotic valve area in the assessment of valvular stenosis, regurgitant orifice area (ROA) represents a fundamental parameter to assess valvular insufficiency. However, this parameter has not been routinely available up to now. In this study, we introduce the concept and provide the methodology to calculate regurgitant orifice area noninvasively, based on the analysis of...

متن کامل

Physiologic Application of the Proximal Flow Convergence Method: Clinical Data and Experimental Testing

Background The proximal flow convergence method, a quantitative color Doppler flow technique, has been validated recently for calculating regurgitant flow and orifice area. We investigated the potential of the method as a tool to study different pathophysiological mechanisms of mitral valve incompetence by assessing the time course of regurgitant flow and orifice area and analyzed the implicati...

متن کامل

Proximal isovelocity surface area should be routinely measured in evaluating mitral regurgitation: a core review.

The proximal isovelocity surface area (PISA) measurement, also known as the "flow convergence" method, can be used in echocardiography to estimate the area of an orifice through which blood flows. It has many applications, but this review focuses only on its use in the intraoperative evaluation of mitral regurgitation. In that setting, PISA provides a quantitative assessment of the severity of ...

متن کامل

Automated flow rate calculations based on digital analysis of flow convergence proximal to regurgitant orifices.

OBJECTIVES The purpose of the study was to develop and validate an automated method for calculating regurgitant flow rate using color Doppler echocardiography. BACKGROUND The proximal flow convergence method is a promising approach to quantitate valvular regurgitation noninvasively because it allows one to calculate regurgitant flow rate and regurgitant orifice area; however, defining the loc...

متن کامل

Effective mitral regurgitant orifice area: clinical use and pitfalls of the proximal isovelocity surface area method.

OBJECTIVES We attempted to determine the accuracy and pitfalls of calculating the mitral regurgitant orifice area with the proximal isovelocity surface area method in a clinical series that included patients with valvular prolapse and eccentric jets. BACKGROUND The effective regurgitant orifice area, a measure of lesion severity of mitral regurgitation, can be calculated by the proximal isove...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 32 4  شماره 

صفحات  -

تاریخ انتشار 1998