Intraoperative brain shift prediction using a 3D inhomogeneous patient-specific finite element model.

نویسندگان

  • Jingwen Hu
  • Xin Jin
  • Jong B Lee
  • Liying Zhang
  • Vipin Chaudhary
  • Murali Guthikonda
  • King H Yang
  • Albert I King
چکیده

OBJECT The aims of this study were to develop a three-dimensional patient-specific finite element (FE) brain model with detailed anatomical structures and appropriate material properties to predict intraoperative brain shift during neurosurgery and to update preoperative magnetic resonance (MR) images using FE modeling for presurgical planning. METHODS A template-based algorithm was developed to build a 3D patient-specific FE brain model. The template model is a 50th percentile male FE brain model with gray and white matter, ventricles, pia mater, dura mater, falx, tentorium, brainstem, and cerebellum. Gravity-induced brain shift after opening of the dura was simulated based on one clinical case of computer-assisted neurosurgery for model validation. Preoperative MR images were updated using an FE model and displayed as intraoperative MR images easily recognizable by surgeons. To demonstrate the potential of FE modeling in presurgical planning, intraoperative brain shift was predicted for two additional head orientations. Two patient-specific FE models were constructed. The mesh quality of the resulting models was as high as that of the template model. One of the two FE models was selected to validate model-predicted brain shift against data acquired on intraoperative MR imaging. The brain shift predicted using the model was greater than that observed intraoperatively but was considered surgically acceptable. CONCLUSIONS A set of algorithms for developing 3D patient-specific FE brain models is presented. Gravity-induced brain shift can be predicted using this model and displayed on high-resolution MR images. This strategy can be used not only for updating intraoperative MR imaging, but also for presurgical planning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serial FEM/XFEM-Based Update of Preoperative Brain Images Using Intraoperative MRI

Current neuronavigation systems cannot adapt to changing intraoperative conditions over time. To overcome this limitation, we present an experimental end-to-end system capable of updating 3D preoperative images in the presence of brain shift and successive resections. The heart of our system is a nonrigid registration technique using a biomechanical model, driven by the deformations of key surf...

متن کامل

Intraoperatively updated neuroimaging using brain modeling and sparse data.

OBJECTIVE Image-guided neurosurgery incorporating preoperatively obtained imaging information is subject to spatial error resulting from intraoperative brain displacement and deformation. A strategy to update preoperative imaging using readily available intraoperative information has been developed and implemented. METHODS Preoperative magnetic resonance imaging is used to generate a patient-...

متن کامل

Real-Time Prediction of Brain Shift Using Nonlinear Finite Element Algorithms

Patient-specific biomechanical models implemented using specialized nonlinear (i.e., taking into account material and geometric nonlinearities) finite element procedures were applied to predict the deformation field within the brain for five cases of craniotomy-induced brain shift. The procedures utilize the Total Lagrangian formulation with explicit time stepping. The loading was defined by pr...

متن کامل

Techniques on mesh generation for the brain shift simulation

Neurosurgery interventions involve complex tracking systems because a tissue deformation takes place. The neuronavigation system relies only on preoperative images. In order to overcome the soft tissue deformations and guarantee the accuracy of the navigation a biomechanical model can be used during surgery to simulate the deformation of the brain. Therefore, a mesh generation for an optimal re...

متن کامل

A study on behavior of block pavement using 3D finite element method

Three dimensioned finite element analysis were conducted on concrete block paving. In order to verify the calculated results, an experimental case study was analyzed. Good agreement was observed between the measured and the calculated results. Based on the finite element analysis results and available failure models, comprehensive design charts were developed for port and industrial pavement wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurosurgery

دوره 106 1  شماره 

صفحات  -

تاریخ انتشار 2007