Effectiveness of mask ventilation in a training mannikin. A comparison between the Oxylator EM100 and the bag-valve device.

نویسندگان

  • J J Osterwalder
  • W Schuhwerk
چکیده

The demands for an optimal ventilation apparatus are that it can be easily handled, achieves a sufficiently high ventilation volume, and minimizes gastric inflation. Our aim was therefore to carry out a study in a training mannikin to find out whether the Oxylator EM100, compared with the bag, obtains improved ventilation and a decrease in gastric inflation. In a randomized crossover study, 72 subjects were selected (24 physicians, 44 nurses and 4 auxiliary nurses), chosen from the operating theatre, emergency department and intensive care unit of two hospitals. We used the Ambu-Bag Mark III with mask No. 4, the Oxylator EM100 with a pressure setting of 35 cm H2O run in the manual setting, the Ambu-Man C mannikin as well as the Ambu-CPR computer program. The resuscitation cycles of the standard two-rescuer's adult procedure lasted 3 min each, with a 3-min pause between the crossover procedure. The participants could improve their ventilatory volume with the Oxylator EM100 by 635 ml (95% confidence interval 578-692 ml) compared with the bag ventilation. The number of subjects who could attain a mean ventilatory volume of 800 ml or more increased from 15% to 98.6% (P < 0.001). Compared with the bag, the increase of adequate respirations (> or = 800 ml) obtained by the Oxylator EM100 for the individual participants amounted to a median of 91% (P < 0.001). Moreover, conventional ventilation caused in 42% one or several instances of gastric inflation, whereas no such reactions occurred with the Oxylator EM100. The Oxylator EM100 showed significantly better results in the mannikin than the bag. Of most importance is a significant lowering of gastric inflation and less so a marked increase in ventilatory volume. Our trial procedure with a relatively high lung compliance and a high oesophageal sphincter opening simulated favorable conditions. Owing to a large in vivo variability of these magnitudes, a direct testing in real patients with circulatory arrest is indicated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of an oxygen-powered flow-limited resuscitator to manual ventilation with an adult 1,000-mL self-inflating bag.

BACKGROUND Positive-pressure ventilation of patients with unprotected airways during cardiopulmonary resuscitation can cause gastric dilation. OBJECTIVE Determine if there is a significant difference in volume delivered to lungs and stomach while using an adult 1,000-mL disposable bag-valve-mask (BVM) device and the oxygen-powered, flow-limited Oxylator EMX resuscitator. METHODS We used a b...

متن کامل

Airway management by first responders when using a bag-valve device and two oxygen-driven resuscitators in 104 patients.

BACKGROUND AND OBJECTIVE To evaluate the capability of first responders to ensure an airway and ventilate the lungs of a patient employing a bag-valve device and two oxygen-driven resuscitators. METHODS Prospective, controlled, blinded, single-centre clinical trial using a bag-valve device and one of two FR-300 devices, with 20 cmH2O working pressure, flows of 24 and 30 L min(-1). One-hundred...

متن کامل

بررسی سهولت تهویه تنفسی با ماسک، با جاگذاری گاز تا شده در

 Back ground & Aims: In the edentulous patients some authors suggest to leave dentures in when ventilating with bag-mask. In this research, we suggest a more efficient method.  Materials & Methods: In the prospective blind randomized clinical trial we included 200 patients (age≥55) into two groups. After induction of anesthesia in all groups, in the group I, we placed folded gauze in each bucca...

متن کامل

مقایسه لوله دهانی حلقی کافدار با لوله تراشه در حفظ راه هوائی و تهویه بیماران تحت بیهوشی عمومی با تنفس خودبخودی

Background: Cuffed pharyngeal tube is a device designed for ventilation of anesthetized patients. CPT has advantages over face mask including: maintaining of face mask can be difficult and boring after several minutes and mobility of the practitioner is reduced due to involvement of hands. Mask pressure can cause soft tissue and nerve damage around the nose. Anesthetic gas leakage from the mask...

متن کامل

Can first responders achieve and maintain normocapnia when sequentially ventilating with a bag-valve device and two oxygen-driven resuscitators? A controlled clinical trial in 104 patients.

BACKGROUND AND OBJECTIVE To evaluate the capability of first responders to achieve and maintain normal ventilation of the lungs of victims employing a bag-valve device and two oxygen-driven resuscitators. METHODS Prospective, controlled, blinded, single-centre clinical trial using a bag-valve device and one of two FR-300 devices, with 20 cmH2O working pressure, and flows of either 24 or 30 L ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Resuscitation

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 1998